Disproportionate Damage

Upcoming CIB/NIST Workshop on Structural Reliability in Fire ?!?

2014-05-16:  Anybody with even the slightest interest in the Future Development of Fire Engineering Design, and Structural Fire Engineering in particular, should pay attention to the proceedings of an upcoming CIB/NIST Workshop, which will be held on 21-22 May 2014, at the NIST Campus in Maryland, USA …

CIB/NIST Fire Resistance/Resistant/Resisting/Resistive Structures Workshop

It is essential to read 3 White Papersproduced by three separate teams of experts, contracted by NIST, in advance of the Workshop … to get a ‘real’ flavour of how discussions may, or may not, develop next week.  All three papers are available to download from the NIST WebSite (and the links below).  I suggest that you get your hands on them … ASAP !

1.   Fire Behaviour of Steel Structures (March 2014).  20 Pages, 786 Kb.
2.   State-of-the-Art on Fire Resistance of Concrete Structures: Structure-Fire Model Validation (March 2014).  32 Pages, 1.26 Mb.
3.   Fire Resistance of Timber Structures (March 2014).  20 Pages, 998 Kb.

After reading these 3 NIST White Papers … I was not surprised by the large number of ‘unknowns’, or the enormous gaps in our ‘knowns’ …

Taken in whole and all together, however, the three documents are a public confirmation that today’s general practice of Fire Engineering is more akin to that of mid-19th Century Alchemy.  Blinkered practitioners are isolated from the building design process … because they have no understanding of that process, and have no means of effective communication with the many other design disciplines involved.  And minimal, i.e. ‘cost-effective'(?), compliance with the limited and inadequate fire safety objectives in current building codes/regulations is widely regarded as the one and only target for their efforts … a minor one compared to the fundamental, long-term target of realizing a Safe, Resilient and Sustainable Built Environment for All.  At the same time, frontline fire service personnel are forced to operate on shoestring budgets … and, when a fire emergency inevitably occurs, they are regarded as nothing more than an expendable resource.

!!  Structure … Does Not A Building Make  !!

Some comments on the 3 NIST White Papers …

A.  The Papers contain a number of important technical errors:

  • A similar Introduction in two of the Papers refers only to the 2005 NIST Report (NCSTAR 1) on the 9-11 Collapse of WTC Buildings 1 & 2 in New York City, which contained 30 Recommendations.  However, NIST published a later Report in 2008 (NCSTAR 1A) on the Collapse of WTC Building 7, which contained a further 13 Recommendations … 1 new, and 12 revised/updated from the earlier 2005 Report.
  • There is a reference in one of the Papers to a 1989 European Directive on Construction Products (89/106/EEC), and as later amended.  This Directive was repealed, in 2011, by Article 65 of the new European Union (EU) Regulation No.305/2011 on Construction Products.  Unlike a Directive, a Regulation is addressed directly to the EU Member States, and does not permit any flexibility with regard to national implementation. Annex I of Regulation 305/2011 sets out 7 Basic Requirements for Construction Works:

–  Mechanical resistance and stability ;
–  Safety in case of fire ;
–  Hygiene, health and the environment ;
–  Safety and accessibility in use ;
–  Protection against noise ;
–  Energy economy and heat retention ;
–  Sustainable use of natural resources.

Concerning fire safety in buildings … it is incorrect to state, or even suggest, that only the second Basic Requirement is relevant … a building must satisfy all of the Basic Requirements taken together, i.e. the 7 Basic Requirements are inter-dependent.

B.  Having carefully read the Papers … none of the expert teams appear to have paid any attention to any of the NIST Recommendations, in either the 2005 or the 2008 Reports !   Note well that two separate series of posts on both sets of NIST Recommendations have been carried here on this Technical Blog.

C.  If we have learned anything from the WTC 9-11 Building Collapses, it is that the Fire Engineer must be able to communicate effectively with other mainstream building design disciplines … especially ‘ambient’ structural engineers who speak the language of Structural Reliability, Limit State Design and Serviceability Limit States.  The Fire Engineer must also become an active participant in the creative, trans-disciplinary process of design.  These issues have not been seriously considered in any of the Papers.

D.  All of the Papers lack a common and precise starting point … relevant structural fire engineering concepts are either not defined or badly defined … and the ‘dynamic, complex architectural interaction between a building’s structure and fabric under conditions of fire’ requires immediate and urgent investigation …

Structural Reliability

The ability of a structural system to fulfil its design purpose, for a specified time,
under the actual environmental conditions encountered in a building.

Structural Fire Engineering

Those aspects of fire engineering concerned with structural design for fire …
and the dynamic, complex architectural interaction between a building’s structure and
fabric, i.e. non-structure … under conditions of fire and its immediate aftermath,
including but not confined to the ‘cooling phase’.

Fire-Induced Progressive Damage

The sequential growth and intensification of structural deformation
and displacement, beyond fire engineering design parameters*, and the eventual failure
of elements of construction in a building – during a fire and the ‘cooling phase’
afterwards – which, if unchecked, will result in disproportionate damage,
and may lead to total building collapse.

[ *fire serviceability limit states ]

.

Disproportionate Damage

The failure of a building’s structural system:
(i) remote from the scene of an isolated overloading action ;
and (ii) to an extent which is not in reasonable proportion to that action.

[ Fire-Induced Progressive Damage and Disproportionate Damage are fundamental concepts in the Fire Engineering Design of All Buildings ! ]

.

E.  It is not acknowledged in any of the Papers that the Fire Safety Objectives in Current Building Codes/Regulations are, of necessity, limited in scope … and entirely inadequate in the context of Annex I in EU Regulation 305/2011, and the long-term goal of realizing a Safe, Resilient and Sustainable Built Environment for All.  Refer to the updated Scope, Aims & Objectives of CIB Working Commission 14: ‘Fire Safety’.

F.  Once and for all … use of the term Fire Resistance (and any number of variations thereof, e.g. resistant, resisting, resistive, etc.) in connection with any aspect of structural performance in fire … is ridiculous !   It is roughly comparable to use of the term Fire Proof during the first half of the 20th Century.

G.  Finally, for now … the current unwise focus on Crude Pass/Fail Results from the ‘standard fire’ testing of single loadbearing structural elements must evolve … must be transformed into the more detailed and precise measurement of all aspects of ‘real’ structural system performance over the full duration of a ‘design’ fire (including the cooling phase afterwards) … using a much wider range of performance monitoring equipment, e.g. short wave infra-red thermography.

.

It is no longer acceptable for Fire Engineering to exist in an isolated Twilight Zone … completely removed from the everyday realities of Mainstream Building & Construction.

.

.

END

Sustainable Fire Engineering Design – Targeting & MRV !

2014-04-20:  Traditional/Conventional Fire Engineering Practice is slowly, but inevitably, being transformed … in order to meet the regional and local challenges of rapid urbanization and climate change, the pressing need for a far more efficient and resilient building stock, and a growing social awareness that ‘sustainability’ demands much greater human creativity …

Design Target:  A Safe, Resilient and Sustainable Built Environment for All

Design Key Words:  Reality – Reliability – Redundancy – Resilience

Essential Construction & Occupancy Start-Up Processes:  Careful Monitoring & Reporting – Independent Verification of Performance (MRV)

.

Sustainable Fire Engineering Design Solutions:

Are Reliability-Based …
The design process is based on competence, practical experience, and an understanding of ‘real’ building performance and resilience during Extreme Man-Made Events, e.g. 2001 WTC 9-11 Attack & 2008 Mumbai Hive Attacks, and Hybrid Disasters, e.g. 2011 Fukushima Nuclear Incident … rather than theory alone.

Are Person-Centred …
‘Real’ people are placed at the centre of creative design endeavours and proper consideration is given to their responsible needs … their health, safety, welfare and security … in the Human Environment, which includes the social, built, economic and virtual environments.

Are Adapted to Local Context & Heritage *
Geography, orientation, climate (including change, variability and severity swings), social need, culture, traditions, economy, building crafts and materials, etc., etc.
[* refer to the 2013 UNESCO Hangzhou Declaration]

In Sustainable Design … there are NO Universal Solutions !

Design Objectives:

To protect society, the best interests of the client/client organization and building user health and safety, and to maintain functionality under the dynamic, complex conditions of fire … Project-Specific Fire Engineering Design Objectives shall cover the following spectrum of issues …

  • Protection of the Health and Safety of All Building Users … including people with activity limitations (2001 WHO ICF), visitors to the building who will be unfamiliar with its layout, and contractors or product/service suppliers temporarily engaged in work or business transactions on site ;
  • Protection of Property from Loss or Damage … including the building, its contents, and adjoining or adjacent properties ;
  • Safety of Firefighters, Rescue Teams and Other Emergency Response Personnel ;
  • Ease and Reasonable Cost of ‘Effective’ Reconstruction, Refurbishment or Repair Works after a Fire ;
  • Sustainability of the Human Environment – including the fitness for intended use and life cycle costing of fire engineering related products, systems, etc … fixed, installed or otherwise incorporated in the building ;
  • Protection of the Natural Environment from Harm, i.e. adverse impacts.

.

More Specifically … with Regard to Resilient Building Performance during a Fire Incident and the ‘Cooling Phase’ after Fire Extinguishment:

1.   The Building shall be designed to comply with the Recommendations in the 2005 & 2008 NIST(USA) Final Reports on the World Trade Center(WTC) 1, 2 & 7 Building Collapses.

In one major respect, the 2005 NIST Report is flawed, i.e. its treatment of ‘disability and building users with activity limitations is entirely inadequate.  The Building shall, therefore, be designed to comply with International Standard ISO 21542: ‘Building Construction – Accessibility & Usability of the Built Environment’, which was published in December 2011.

2.   The Building shall remain Serviceable, not just Structurally Stable(!) … until all buildings users (including those users with activity limitations waiting in ‘areas of rescue assistance’) have been evacuated/rescued to an accessible ‘place of safety’ which is remote from the building, and have been identified … and all firefighters, rescue teams and other emergency response personnel have been removed/rescued from the building and its vicinity.

The Building shall be designed to resist Fire-Induced Progressive Damage and Disproportionate Damage.  These requirements shall apply to all building types, of any height.

Under no reasonably foreseeable circumstances shall the Building be permitted to collapse !

3.   The Building shall be designed to comfortably accommodate and resist a Maximum Credible Fire Scenario and a Maximum Credible User Scenario.

.

Concerted International Research is Needed …

To creatively resolve the direct conflict which exists between Sustainable Building Design Strategies and Traditional/Conventional Fire Engineering.

An example … for cooling, heating and/or ventilation purposes in a sustainable building, it is necessary to take advantage of natural patterns of uninterrupted air movement in that building. On the other hand, fire consultants in private practice, and fire prevention officers in authorities having jurisdiction, will demand that building spaces be strictly compartmented in order to limit the spread of fire and smoke … thereby dramatically interfering with those natural patterns of air movement. The result is that the sustainability performance of the building is seriously compromised.

If, however, adequate independent technical control is absent on the site of a sustainable building … it is the fire safety and protection which will be seriously compromised !

To effectively deal with the fire safety problems (fatal, in the case of firefighters) which result from the installation of Innovative Building/Energy/EICT Systems and Products in Sustainable Buildings.

.

These are appropriate tasks for a new CIB W14 Research Working Group VI: ‘Sustainable Fire Engineering Design & Construction’ !

.

.

ENDEnhanced by Zemanta

Upcoming Building Research Workshop at Galway University

2013-06-08:  Looking forward to some serious, collaborative and multi-disciplinary discussions on the day … and a barrel of laughs in the process (!!) …

The Informatics Research Unit for Sustainable Engineering (IRUSE) in the Department of Civil Engineering … and The Ryan Institute for Environmental, Marine and Energy Research … both at the National University of Ireland Galway (NUIG) … have jointly organized a 1-Day National Research Networking Workshop which will take place on Monday, 24 June 2013.

The NUIG ‘blurb’ for the day states … “Considering the importance of aggressive energy-efficiency measures in the Building Sector, together with the requirements for a safe, healthy, comfortable (and accessible) Built Environment … this NUIG Workshop will explore the topic of Integrated Modelling and Performance of the Built Environment.”

.

I was very pleased to receive an invitation to make a Presentation at this prestigious event …

‘Sustainable Fire Engineering Design’  –  My Presentation Abstract

Fire Engineering … involves much more than mere compliance with building regulations and codes … whose fire safety objectives are limited, and whose performance requirements are sometimes inadequate and always minimal.  More problematically … a fundamental conflict is mushrooming between Safe Sustainable Climate Resilient Building Design and Conventional Fire Consultancy Practice.

However … Sustainable Fire Engineering Design Solutions are:

  • Reliability-based ;
  • Person-centred ;

and above all

  • Adapted to Local Context and Heritage (fr: le Patrimoine – see ICOMOS 2011) … geography, climate (incl. change, variability and severity swings), social need, culture, and economy, etc., etc.

This Presentation will discuss very rich collaborative research potential in the following areas …

  1. Creative Fire Engineering Concepts and Building Systems
  2. Fire-Induced Progressive Damage in Buildings
  3. Human Behaviour and Abilities in a Fire Situation
  4. Building Design for Firefighter Safety
  5. BMS – Fire Modelling – BIM

Research Output must be targeted at practical implementation in ‘real’ buildings … with actual user/construction performance carefully (i.e. reliably and precisely) monitored !

.

If anybody out there is interested in attending this NUIG Research Workshop … please contact Ms. Magdalena Hajdukiewicz (IRUSE) at: hajdukiewicz1@nuigalway.ie

.

.

POST-EVENT UPDATE:  2013-06-27 …

While it was difficult to keep the Workshop Programme, involving a series of short 10-minute presentation slots, on track … discussions during the day were engaging, energetic and extensive.

I happily look forward to a successful and collaborative outcome from the day … Multi-Disciplinary Teams producing Trans-Disciplinary Research Output … which is geared towards practical implementation in ‘real’ buildings, with actual construction and building user performance carefully (i.e. reliably and precisely) monitored !

Galway University (NUIG) Workshop Programme & Presentation Abstracts

Click the Link Above to read and/or download PDF File (193 Kb)

Galway University (NUIG) Built Environment Research Networking Workshop - 24 June 2013
Colour photograph showing the venue for the IRUSE & The Ryan Institute (Galway University – NUIG) Built Environment Research Networking Workshop, which was held in the New Engineering Building on 24 June 2013. Seen here is Dr. Harald Berresheim during his presentation on ‘The Self-Cleansing Capacity of Our Atmosphere – Limitations on Local to Global Scales’. Photograph taken by CJ Walsh. 2013-06-24. Click to enlarge.

.

CJ Walsh Presentation: ‘Sustainable Fire Engineering Design’

Click the Link Above to read and/or download PDF File (1.78 MB)

.

However … and especially since the Workshop had been organized by IRUSE (the ‘SE’ standing for ‘Sustainable Engineering’) … it was indeed very strange to have to clarify the following points, among others:

1.   The Minimum Life Cycle for a Sustainable Building is 100 Years … not 50 or 60 years !

2.   Future Research Collaboration should be targeted at the multi-aspect ‘Sustainability Agenda’.  The word ‘green’ (where only environmental aspects of sustainability are considered) should be actively discouraged, if not banned entirely !

3.   With regard to Good Indoor Air Quality (IAQ) … two high-level performance indicators which have been developed with the aim of protecting human health, and are both now referenced in International Standard ISO 21542: ‘Building Construction – Accessibility & Usability of the Built Environment’ … are …

      –   Radon Activity (incl. Rn-222, Rn-220, RnD) in a building should, on average, fall within the range of 10 Bq/m3 to 40 Bq/m3, but should at no time exceed 60 Bq/m3 ;

      –   Carbon Dioxide (CO2) Concentrations in a building should not significantly exceed average external levels – typically within the range of 300 parts per million (ppm) to 500 ppm – and should at no time exceed 800 ppm.

.

Galway University’s New Engineering Building

Concerning the substantive difference in meaning and scope between ‘sustainable’ and ‘green’ … there is, perhaps, no better way to illustrate this difference than to observe the atrocious ‘Accessibility-for-All’ Performance (Accessibility for People with Activity Limitations !) of the critically acclaimed (?!?) and award winning (?!?) New Engineering Building in Galway University … which flaunts its ‘über-green’ credentials …

Galway University's New Engineering Building - Inadequate Accessibility-for-All (1)

Galway University's New Engineering Building - Inadequate Accessibility-for-All (2)

Galway University's New Engineering Building - Inadequate Accessibility-for-All (3)

Galway University's New Engineering Building - Inadequate Accessibility-for-All (4)

Galway University's New Engineering Building - Inadequate Accessibility-for-All (5)

Can you believe what’s in those photographs ??   More importantly … can you believe what’s not in those photographs ????   In such a recently completed building … “incredible” is the only answer to both questions.

.

Under International Law … lack of accessibility, or inadequate accessibility, to the social, built, virtual and economic environments … IS a denial and infringement of the basic human rights of people with activity limitations.  It also limits, needlessly and unnecessarily, the numbers of potential users of those environments … which makes no sense at all.

My strong recommendation to Galway University … is to immediately commission a Competent Accessibility Consultant to give the university campus a thorough going over !   You are failing the campus user population … the local community in Galway … and Irish society generally.

My even stronger recommendation to the Architects for the New Engineering BuildingRMJM Architects (Robert Matthew Johnson-Marshall) in Scotland, and Taylor Architects in Ireland … is to always commission a Competent Accessibility Consultant on all of your projects … small, medium and large … because you haven’t a bull’s notion about this important dimension of building performance !!

And remember folks … Accessibility has been clearly specified in the new International Standard ISO 21542 as including … ‘access to buildings, circulation within buildings and their use, egress from buildings in the normal course of events, and evacuation in the event of an emergency’.

.

.

END

 

Enhanced by Zemanta

‘Sustainable Fire Engineering for All’ – SDI’s Professional Service

2012-12-14 & 2012-12-30:  Further to this distressing incident … which exposed a profound lack of awareness, care and competence within the general fire safety industrial sector …

Recent Fatal Fire at a Disabled Workshop in SW Germany

… this is how we would like to help you … whether you are an individual, or an organization … whether you are located in Ireland, Italy or Turkey … some other part of Europe, the Arab Gulf Region, India, Japan, China … or wherever !

And … we can, if requested or necessary, work in collaboration with local partners in those different geographical regions.

– FireOx International is the Fire Engineering Division of Sustainable Design International Ltd. (SDI) –

.

Colour photograph showing the 2 World Trade Center Towers, in New York City, immediately after the second plane impact. The mechanical damage arising from such a plane impact had been considered in the Initial Building Design Process; incredibly, any type of Fire Incident had not ! In the case of both towers and within a short period of time, Fire-Induced Progressive Damage resulted in Disproportionate Damage, and eventual Total Building Collapse. The horror and carnage at the World Trade Center Complex, and the extensive collateral damage to everywhere south of Canal Street, caused enormous long-term damage to the economy of Manhattan ... and had a very significant adverse impact on Global Financial Markets. Click to enlarge.
Colour photograph showing the 2 World Trade Center Towers, in New York City, immediately after the second plane impact. The mechanical damage arising from such a plane impact had been considered in the Initial Building Design Process; incredibly, any type of Fire Incident had not ! In the case of both towers and within a short period of time, Fire-Induced Progressive Damage resulted in Disproportionate Damage, and eventual Total Building Collapse. The horror and carnage at the World Trade Center Complex also caused enormous long-term damage to the economy of Manhattan … and had a very significant adverse impact on Global Financial Markets. Click to enlarge.

.

Introduction

Fundamentally, the 9-11 World Trade Center Incident in New York (2001) was an Extreme ‘Real’ Fire Event.  It presented the International Fire Engineering Community with a catastrophic failure in conventional practices and procedures related to:

  • Fire Engineering, Structural Engineering, and Architectural Design ;
  • Human Building Management Systems ;
  • Emergency Response by Firefighters, Rescue Teams, and Medical Personnel ;
  • National and Local Organizations Having Authority or Jurisdiction (AHJ’s) ;

… and with the serious problem of entirely inadequate Fire Safety Objectives in the building legislation, model codes and design standards of the most economically advanced countries in the world.

Those people who understand the building design process, and have experience as construction practitioners, have long realised that the lessons from 9-11 must be applied across the full spectrum of building types … not just to tall buildings.  Right up to the present day, unfortunately, many people in the International Fire Engineering Community are either unwilling, or unable, to do this.

Furthermore … Fire Engineering, Architectural Design and Structural Engineering must, of urgent necessity, be seamlessly conjoined … with the aim of removing misunderstandings and the wide gaps in client service delivery between the different disciplines.

In 2002, a series of Long-Term 9-11 Survivor Health Studies commenced in the USA … and in 2005 and 2008, the U.S. National Institute of Standards and Technology (NIST) issued a series of Post 9-11 Critical Recommendations concerning the design, construction, management and operation of buildings.

At FireOx International … we have fully integrated this essential design guidance into our frontline fire engineering and architectural practice … we have developed unique and practical solutions for worldwide application, some of which appear in International Standard ISO 21542: ‘Building Construction – Accessibility & Usability of the Built Environment’, published in December 2011.

.

Colour photograph showing an armed assailant during the November 2008 'Hive-Attack' on Mumbai ... an extraordinarily violent, co-ordinated assault on the largest (and wealthiest) city in India, which involved the strategic targeting of built environment Places of Public Resort, Iconic Buildings, High-Rise Buildings, Buildings having a Critical Function, Transport Infrastructure and Service Utilities ... with the aim of causing widespread terror among the general population, including tourists, and disruption to the city’s important economic environment. Click to enlarge.
Colour photograph showing an armed assailant during the November 2008 ‘Hive-Attack’ on Mumbai … an extraordinarily violent, co-ordinated assault on the largest (and wealthiest) city in India, which involved the strategic targeting of built environment Places of Public Resort, Iconic Buildings, High-Rise Buildings, Buildings having a Critical Function, Transport Infrastructure and Service Utilities … with the aim of causing widespread terror among the general population, including tourists, and disruption to the city’s important economic environment. Click to enlarge.

.

FireOx International’s Commitment to You

As a necessary response to the New 21st Century Paradigm of Real Extreme Event in a Built Environment which is becoming more and more complex … is subject to climate change and severe weather events … and is vulnerable to malign and malevolent disruption –

WE are committed to … the implementation of a Sustainable Human Environment which is Fire Safe and Secure for All, meaning that an ‘appropriate project-specific fire safety level’ is our fire engineering objective, with ‘human health protection’ targeted as a priority … through the use of innovative, reliability-based and person-centred sustainable design practices and procedures.

.

What is an ‘Appropriate Fire Safety Level’ in Your Building or Facility ?

It is rarely, if ever, explained to clients/client organizations that the Minimal Fire Safety Objectives in building legislation are focused solely on protecting the ‘interests’ of society, not those of the individual …  are, quite often, inadequate and/or flawed … and are, always, revised only after the latest tragedy !

To properly protect Your Interests as a client/client organization … we strongly advise that the Appropriate Level of Fire Safety in Your Building or Facility should exceed the minimal level of safety required by building legislation.  We would also caution that, in many jurisdictions (e.g. India), compliance with national building legislation is voluntary.

Which raises the issues of whether or not you will actually get what you pay for, and whether or not the Fire Protection Measures in Your Building or Facility are reliable (in other words, will they perform as intended at the time of a ‘real’ fire, which may occur at any time in a building’s long life cycle) !?!   Competent Technical Control of Design and Construction, independent of the design and construction organization(s), is essential.

You should carefully consider the following spectrum of issues which may be directly relevant to Your Project.  Following a process of consultation with you, we then develop Project-Specific Fire Engineering Design Objectives … bearing in mind that you must also comply with safety at work, anti-discrimination, and environmental legislation, etc … maintain business continuity, etc … be energy efficient, etc … and be socially responsible, etc …

–     Protection of the Health of All Building Users … including People with Activity Limitations (2001 WHO ICF), Visitors to the building or facility who may be unfamiliar with its layout, and Contractors or Product/Service Suppliers temporarily engaged in work or business transactions on site ;

–     Protection of Property from Loss or Damage … including the Building or Facility, its Contents, and Adjoining or Adjacent Properties ;

–     Safety of Firefighters, Rescue Teams and Other Emergency Response Personnel ;

–     Ease and Reasonable Cost of ‘Effective’ Reconstruction, Refurbishment or Repair Works after a Fire ;

–     Sustainability of the Human Environment (social – built – virtual – economic) … including Fitness for Intended Use and Life Cycle Costing of fire engineering related products and systems, etc … fixed, installed or otherwise incorporated in the building or facility ;

–     Protection of the Natural Environment from Harm, i.e. Adverse or Damaging Impacts.

.

FireOx International – Our Fire Engineering Services

  • WE  will advise you on Fire Safety Policy, Fire Safety Strategy Development, Fire Safety Implementation … and, whether you are within or from outside the European Union, on CE Marking of Fire Protection Related Construction Products

  • WE  understand the process of Design, particularly the new language of Sustainable Design … and we will produce Creative Fire Engineering Solutions for Your Project

  • WE  are thoroughly familiar with the intricacies of Building Sites … and we will verify and/or validate Design Compliance during construction, and at project completion … and, if requested or necessary, as a completely Independent Technical Controller ; 

  • WE  communicate easily and effectively with other Professional Design Disciplines, including architects and structural engineers … and we will act as fully participating members of Your Project Design & Construction Team … and, if requested or necessary, as the Design Professional in Responsible Charge **

  • WE  practice in accordance with a comprehensive Professional Code of Ethics

.

Sustainable Fire Engineering Solutions ?

  1. Are adapted to Local Geography, Climate/Climate Change, Social Need, Culture, Economy … and Severe Events (e.g. earthquakes, flooding) ;
  2. Are ‘Reliability-Based’, i.e. that design process based on practical experience, competence and an examination of real extreme events, e.g. 2001 WTC 9-11 & 2008 Mumbai Attacks, and 2011 Fukushima Nuclear Incident … rather than theory alone ;
  3. Are ‘Person-Centred’, i.e. that design process which places ‘real’ people at the centre of creative endeavours and gives due consideration to their responsible needs, and their health, safety, welfare and security in the Human Environment.

.

FireOx International’s Contact Information

E-Mail:  cjwalsh@sustainable-design.ie

International Phone:  +353 1 8386078   /   National Phone:  (01) 8386078

.

.

Important Note:  This Post should be read in conjunction with an earlier Post …

Sustainable Design International Ltd. – Our Practice Philosophy

It is there, not here, that we define Sustainable Human & Social Development … and describe how our Practice is responding to this open, intricate, dynamic, and still evolving concept.  The resulting transformation in how frontline services are provided to our Clients/Client Organizations ensures a much more comfortable ‘fit’ to their needs … and a greater level of protection, safety and security for society !

.

[ ** 2005 NIST(USA) Final Report on 9-11 World Trade Center 1 & 2 Tower Collapses

– Footnote 49 –

… the Design Professional in Responsible Chargeusually the lead architect – ensures that the (Design) Team Members use consistent design data and assumptions, co-ordinates overlapping specifications, and serves as the liaison with enforcement and review officials, and with the client or client organization. ]

.

.

END

Enhanced by Zemanta

Sustainable Design International Ltd. – Our Practice Philosophy

2012-10-25:   The Practice Philosophy of Sustainable Design International Ltd. is an issue which has occupied my mind greatly during this past summer … as I asked myself some difficult questions …

What has really been happening to our planet since 1992 … and earlier, since 1972 ?

Where is SDI now ?

Are we on the same track … the right track ?

Where are we going in the short to medium-term future ?

Architecture … is practice as a separate design disciple now obsolete ?

Fire Engineering … can it be dragged, screaming, from the proverbial ‘caves’ … and transformed to respond creatively to the safety and security requirements of a complex built environment ?

Sustainability … what impact does this intricate, open, dynamic and still evolving concept have … should it have … on the provision of conventional Architectural and Fire Engineering Services ?

‘Green’ … is this marketing ploy helpful … or an annoying obstacle … to effective implementation of Sustainable Development ?

.

.

WBCSD's Vision 2050 Poster (2010)World Business Council for Sustainable Development (WBCSD)

Vision 2050: ‘The New Agenda for Business’ (2010)

Click the Link Above to read and/or download a PDF File (3.73 Mb)

.

.

Colour image showing the Tile Page of 'Keeping Track of Our Changing Environment: From Rio to Rio+20 (1992-2012)' ... published in 2011 by the Division of Early Warning and Assessment (DEWA), United Nations Environment Programme (UNEP), Nairobi. Click to enlarge.
Colour image showing the Tile Page of ‘Keeping Track of Our Changing Environment: From Rio to Rio+20 (1992-2012)’ … published in 2011 by the Division of Early Warning and Assessment (DEWA), United Nations Environment Programme (UNEP), Nairobi. Click to enlarge.

2011 – United Nations Environment Programme

Keeping Track of Our Changing Environment: From Rio to Rio+20 (1992-2012)

Click the Link Above to read and/or download a PDF File (4.83 Mb)

Extract from ‘Foreword’ …

This publication serves as a timely update on what has occurred since the Earth Summit of 1992 and is part of the wider Global Environment Outlook-5 (GEO-5) preparations that will lead to the release of the landmark GEO-5 report in May 2012.  It underlines how in just twenty years, the world has changed more than most of us could ever have imagined – geopolitically, economically, socially and environmentally.  Very few individuals outside academic and research communities envisaged the rapid pace of change or foresaw developments such as the phenomenal growth in information and communication technologies, ever-accelerating globalization, private sector investments across the world, and the rapid economic rise of a number of ‘developing’ countries.  Many rapid changes have also taken place in our environment, from the accumulating evidence of climate change and its very visible impacts on our planet, to biodiversity loss and species extinctions, further degradation of land surfaces and the deteriorating quality of oceans.  Certainly, there have been some improvements in the environmental realm, such as the significant reduction in ozone-depleting chemicals and the emergence of renewable energy sources, new investments into which totalled more than $200 thousand million in 2010.  But in too many areas, the environmental dials continue to head into the red.

Achim Steiner, United Nations Under-Secretary-General, and Executive Director, United Nations Environment Programme (UNEP), Nairobi.

.

Sustainable Design International Ltd. – Ireland, Italy & Turkey

[ http://www.sustainable-design.ie/ ] 

SDI Practice Philosophy Explained (October 2012)

Click the Link Above to read and/or download a PDF File (670 Kb)

SDI  is a professional, trans-disciplinary and collaborative design, architectural, fire engineering, research, and consultancy practice … specialists in the theory and practical implementation of a Sustainable Human Environment (social – built – virtual – economic).

WE are committed to … the protection of society, the best interests of our clients, and ‘user’ welfare … not just cost-effective compliance with the Minimal Health & Safety Objectives in Legislation & Codes !

Sustainability … continues to fundamentally transform our Architectural, Fire Engineering & Consultancy Practice.

.

.

2012 Sustainable Society Index - World View at a Glance
Colour image showing the Sustainable Society Index World View for 2012 … presenting the world average scores for 21 Sustainability Performance Indicators. The inner circle of the spider’s web represents a score of 1, meaning no sustainability at all, while the outer ring represents a perfect score of 10 or full sustainability. Click to enlarge.

Sustainable Society Foundation – The Netherlands

.

.

Colour image showing the Tile Page of 'Measuring Progress: Environmental Goals & Gaps' ... published in 2012 by the Division of Early Warning and Assessment (DEWA), United Nations Environment Programme (UNEP), Nairobi. Click to enlarge.
Colour image showing the Tile Page of ‘Measuring Progress: Environmental Goals & Gaps’ … published in 2012 by the Division of Early Warning and Assessment (DEWA), United Nations Environment Programme (UNEP), Nairobi. Click to enlarge.

2012 – United Nations Environment Programme

Measuring Progress: Environmental Goals & Gaps

Click the Link Above to read and/or download a PDF File (4.72 Mb)

‘Foreword’ …

If we measured the world’s response to environmental challenges solely by the number of treaties and agreements that have been adopted, then the situation looks impressive.  Over 500 international environmental agreements have been concluded since 1972, the year of the Stockholm Conference and the establishment of the United Nations Environment Programme (UNEP).

These include landmark conventions on issues such as trade in endangered species, hazardous wastes, climate change, biological diversity and desertification.  Collectively, these reflect an extraordinary effort to install the policies, aims and desires of countries worldwide to achieve sustainable development.

Yet despite the impressive number of legal texts and many good intentions, real progress in solving the environmental challenges themselves has been much less comprehensive, a point clearly underlined in the Global Environment Outlook-5 (GEO-5), for which this report ‘Measuring Progress: Environmental Goals and Gaps’ and a previous publication ‘Keeping Track of Our Changing Environment: From Rio to Rio+20’ are companion products leading up to Rio+20.

This report outlines findings from a UNEP study that, with support from the Government of Switzerland, has catalogued and analyzed existing ‘Global Environmental Goals’ contained in the international agreements and conventions.  It asks the fundamental question as to why the aims and goals of these policy instruments have often fallen far short of their original ambition and intentions.  One possible reason is that many of the goals are simply not specific enough;  the few goals that are specific and measurable appear to have a much better record of success.

These include goals to phase out lead in gasoline, ozone-depleting substances (ODS) and certain persistent organic pollutants (POP’s), specific Millennium Development Goal targets calling to halve the number of people without access to safe drinking water and improved sanitation, and targets to increase the number and extent of protected areas.  Indeed, even when measurable targets have been set but not actually met, they have usually led to positive change and often to significant change.

The vast majority of goals, however, are found to be ‘aspirational’ in nature.  They lack specific targets, which generate obvious difficulties in measuring progress towards them.  In addition, many aspirational goals are not supported by adequate data that can be used to measure progress, global freshwater quality being one stark example.

It is clear that if agreements and conventions are to achieve their intended purpose, the international community needs to consider specific and measurable goals when designing such treaties, while organizing the required data gathering and putting in place proper tracking systems from the outset.

A set of Sustainable Development Goals, as proposed by the UN Secretary-General’s High-Level Panel on Sustainability, could be an excellent opportunity and starting point to improve this situation while representing another positive outcome from Rio+20, two decades after the Rio Earth Summit of 1992 and four decades after the Stockholm Conference.

Achim Steiner, United Nations Under-Secretary-General, and Executive Director, United Nations Environment Programme (UNEP), Nairobi.

.

.

END

Enhanced by Zemanta

Conventional Structural Fire Engineering Design – How Flawed ?

2012-05-18:  Déjà-vu …

” In the early hours of the morning of Saturday, 14th February 1981, a disastrous fire swept through a building called the Stardust in the North Dublin suburb of Artane during the course of a St. Valentine’s Night ‘disco’ dance.  Forty eight people were killed and one hundred and twenty eight seriously injured.  The overwhelming majority of the victims were young people. “

‘Introduction’, Report of the Tribunal of Inquiry on the Fire at the Stardust, Artane, Dublin, on the 14th February 1981.  Report dated 30 June 1982.

As a young architect in private practice … I witnessed, at first hand, the Dublin Fire ‘Establishment’ disappear from public view, without trace, after the Stardust Fire Tragedy.  It was almost impossible, for at least a year afterwards, to have a meeting with any Fire Prevention Officer in the Dublin Fire Authority.  This was a very valuable lesson.

Later, following the publication of the Stardust Tribunal Report … were its Recommendations implemented … with urgency … and conscientiously ?   No way.  For example, it was more than ten years after the Stardust Fire before an inadequate system of legal National Building Regulations was introduced in Ireland.  And to this day, the system of AHJ monitoring of construction quality, throughout the country, is weak and ineffective … lacking both competent personnel and resources !

The proof of the pudding is in the eating … and one of the results, also in Dublin, has been last year’s debacle at the Priory Hall Apartment Complex … where all of the residents had to leave their expensive apartments for fire safety (and many other) reasons.  The tip of a very large iceberg.  See my post, dated 18 October 2011 .

And this is where the problems usually begin …

” There has been a tendency among students of architecture and engineering to regard fire safety as simply a question of knowing what is required in terms of compliance with the regulations.  The recommendation of the Tribunal of Enquiry into the Summerland Disaster that those responsible for the design of buildings should treat fire safety as an integral part of the design concept itself, has not yet been reflected in the approach to the subject at university level.  There is still clearly a need for a new approach to the structuring of such courses which will in time bring to an end the attitude of mind, too prevalent at the moment, that compliance with fire safety requirements is something that can be dealt with outside the context of the overall design of the building. “

‘Chapter 9 – Conclusions & Recommendations’, Report of the Tribunal of Inquiry on the Fire at the Stardust, Artane, Dublin, on the 14th February 1981.  Report dated 30 June 1982.

This Recommendation has still not been implemented … and note the reference to the earlier fire at the Summerland Leisure Centre in 1973, on the Isle of Man, when 50 people were killed and 80 seriously injured.

Today … the same attitude of mind, described so well above, stubbornly persists in all sectors, and in all disciplines, of the International Construction Industry … even within ISO Technical Committee 92: ‘Fire Safety’ !

.

Which brings me, neatly, to the recent question posed by Mr. Glenn Horton on the Society of Fire Protection Engineers (SFPE-USA) Page of LinkedIn ( http://www.linkedin.com/groups?gid=96627 ).   As usual, the shortest questions can prove to be the most difficult to answer …

” Can you expand on, or point to where anyone has discussed, the ‘very flawed design approach’ please ? “

.

ESSENTIAL PRELIMINARIES …

     1.  Foundation Documents

I am assuming that ‘people-who-need-to know’, at international level, are familiar with the Recommendations contained in these 2 Reports …

  • NIST (National Institute of Standards and Technology).  September 2005.  Federal Building and Fire Safety Investigation of the World Trade Center Disaster: Final Report on the Collapse of the World Trade Center Towers.  NIST NCSTAR 1   Gaithersburg, MD, USA ;

and

  • NIST (National Institute of Standards and Technology).  August 2008.  Federal Building and Fire Safety Investigation of the World Trade Center Disaster: Final Report on the Collapse of World Trade Center Building 7.  NIST NCSTAR 1A   Gaithersburg, MD, USA ;

… and the contents of the CIB W14 Research WG IV Reflection Document … which, together with its 2 Appendices, can be downloaded from this webpage … https://www.cjwalsh.ie/progressive-collapse-fire/ … under the section headed: ‘April 2012’.

However … I am utterly dismayed by the number of ‘people-who-need-to know’ … who do not know … and have never even bothered to dip into the 2 NIST Reports … or the many long-term Post 9-11 Health Studies on Survivors which have already revealed much priceless ‘real’ information about the short and medium term adverse impacts on human health caused by fire !

CIB W14 Research Working Group IV would again strongly caution that Fire-Induced Progressive Damage and Disproportionate Damage are fundamental concepts to be applied in the structural design of all building types.

.

     2.  Technical Terminology

While attending the ISO TC92 Meetings in Thessaloniki, during the last week of April 2012, I noticed not just one reference to ‘fire doors’ in a Draft ISO Fire Standard … but many.  It surprised me, since I thought this issue had been successfully resolved, at ISO level, many years ago.  There is no such thing as a ‘fire door’ … and the careless referencing of such an object, which has no meaning, in building codes and standards has caused countless problems on real construction sites during the last 20-30 years.

Please follow this line of thought …

Fire Resistance:  The inherent capability of a building assembly, or an element of construction, to resist the passage of heat, smoke and flame for a specified time during a fire.

Doorset:  A building component consisting of a fixed part (the door frame), one or more movable parts (the door leaves), and their hardware, the function of which is to allow, or to prevent, access and egress.

[Commentary: A doorset may also include a door saddle / sill / threshold.]

Fire Resisting Doorset / Shutter Assembly:  A doorset / shutter assembly, properly installed or mounted on site, the function of which is to resist the passage of heat, smoke and flame for a specified time during a fire.

… and so we arrive at the correct term … Fire Resisting Doorset … which, as an added bonus, also alerts building designers, construction organizations, and even AHJ inspectors, to the fact that there is more involved here than merely a door leaf.

Now then, I wonder … how, in any sane and rational world, can the term Fire Resistance be used in relation to structural performance during a fire, and the cooling-phase afterwards ?   Yet, this is exactly what I read in the building codes of many different jurisdictions.  Do people understand what is actually going on ?   Or, is the language of Conventional Fire Engineering so illogical and opaque that it is nearly impossible to understand ?

And … if this problem exists within the International Fire Science & Engineering Community … how is it possible to communicate effectively with other design disciplines at any stage during real construction projects.  The artificial environments found in academia are not my immediate concern.

.

     3.  Fire Research & Development outside CIB W14 & ISO TC92

In 2012 … there is something very wrong when you have to struggle to persuade a group of people who are developing an ISO Standard on Design Fire Scenarios … that they must consider Environmental Impact as one of the major consequences of a fire to be minimized … along with ‘property losses’ and ‘occupant impact’.  This is no longer an option.

Environmental Impact:  Any effect caused by a given activity on the environment, including human health, safety and welfare, flora, fauna, soil, air, water, and especially representative samples of natural ecosystems, climate, landscape and historical monuments or other physical structures, or the interactions among these factors; it also includes effects on accessibility, cultural heritage or socio-economic conditions resulting from alterations to those factors.

So … how timely, and relevant to practitioners, are ISO Fire Standards ?   Perhaps … obsolete at publication … and not very ??

And … there is lot more to the Built Environment than buildings …

Built Environment:  Anywhere there is, or has been, a man-made or wrought (worked) intervention in the natural environment, e.g. cities, towns, villages, rural settlements, service utilities, transport systems, roads, bridges, tunnels, and cultivated lands, lakes, rivers, coasts, and seas, etc … including the virtual environment.

.

We should be very conscious that valuable fire-related research takes place outside, and unrelated to, the established fire engineering groupings of CIB W14 & ISO TC92.  But I am curious as to why this research is not properly acknowledged by, or encouraged and fostered within, the ‘system’ ?

Example A:  Responding to Recommendation 18 in the 2005 NIST WTC Report … a Multi-Disciplinary Design Team published an article in the magazine Bâtiment et Sécurité (October 2005) on The PolyCentric Tower.  I very much enjoy giving practitioners a small flavour of this work, whenever I make presentations at conferences and workshops …

Colour image, from one of my Overhead Presentations ... showing The PolyCentric Tower (2005), developed by a French Multi-Disciplinary Design Team in response to Recommendation 18 in the 2005 NIST WTC Report. Click to enlarge.
Colour image, from one of my Overhead Presentations ... showing The PolyCentric Tower (2005), developed by a French Multi-Disciplinary Design Team in response to Recommendation 18 in the 2005 NIST WTC Report. Click to enlarge.

.

Example B:  In spite of a less than helpful submission (to put it mildly) from ISO TC92 Sub-Committee 4 … ISO 21542: ‘Building Construction – Accessibility & Usability of the Built Environment’ was finally published in December 2011 … but it was developed by a Sub-Committee of ISO TC59: ‘Buildings & Civil Engineering Works’

Colour image, from one of my Overhead Presentations ... showing the design of a notional Fire Evacuation Staircase, with an adjoining Area of Rescue Assistance, which responds directly to the 2005 NIST WTC Recommendations. See Figure 62 in ISO 21542:2011. Click to enlarge.
Colour image, from one of my Overhead Presentations ... showing the design of a notional Fire Evacuation Staircase, with an adjoining Area of Rescue Assistance, which responds directly to the 2005 NIST WTC Recommendations. See Figure 62 in ISO 21542:2011. Click to enlarge.

.

With the involvement and support of ISO Technical Committee 178: ‘Lifts, Elevators & Moving Walks’ during its long gestation … ISO 21542 is now able to indicate that all lifts/elevators in a building should be capable of being used for evacuation in the event of a fire.  This is already a design feature in a small number of completed Tall Building Projects.  Once more, this is no longer an option.

In addition … if a Fire Evacuation Staircase has a minimum unobstructed width of 1.5 m (from edge of handrail on one side of the staircase to edge of handrail on the opposite side) … this will be sufficient to facilitate the following tasks …

  • Assisted Evacuation by others, or Rescue by Firefighters, for those building users who cannot independently evacuate the building, e.g. people with activity limitations … shown above, on the right, is assistance being given by three people (one at each side, with one behind) to a person occupying a manual wheelchair ;
  • Contraflow Circulation … emergency access by firefighters entering a building and moving towards a fire, while people are still evacuating from the building to a ‘place of safety’ remote from the building … shown above, bottom left, is how not to design an evacuation staircase (!) ;
  • Stretcher Lifting … lifting a mobility-impaired person, who may be conscious or unconscious, on a stretcher ;
  • Firefighter Removal & Contraflow … shown above, top left, is removal of a firefighter from a building by colleagues in the event of injury, impairment, or a fire event induced health condition … while other firefighters may still be moving towards the fire.

Note that in a Fire Evacuation Staircase … all Handrails are continuous … each Stair Riser is a consistent 150 mm high … each Stair Tread/Going is a consistent 300 mm deep … and there are No Projecting Stair Nosings.

Most importantly … in order to assign sufficient building user space in the design of an Area of Rescue Assistance … ISO 21542 also provides the following Key Performance Indicator … just one aspect of a ‘maximum credible user scenario’ …

10% of people using a building (including visitors) have an impairment, which may be visual or hearing, mental, cognitive or psychological, or may be related to physical function, with some impairments not being identifiable.

Is There Any Connection Between Examples A & B ?   There is, and it is a connection which is critical for public safety.  The following Performance Indicator illustrates the point …

Innovative Structural Design – Perimeter Core Location – Design for Fire Evacuation – Evacuation for All

” A Building must not only remain Structurally Stable during a fire event, it must remain Serviceable for a period of time which facilitates:

  • Rescue by Firefighters of people with activity limitations waiting in areas of rescue assistance ;
  • Movement of the firefighters and those people with activity limitations, via safe and accessible routes, to Places of Safety remote from the building ;
  • With an assurance of Health, Safety & Welfare during the course of this process of Assisted Evacuation. “

[Refer also to the Basic Requirements for Construction Works in Annex I of the European Union’s Construction Product Regulation 305/2011 – included as Appendix II of the CIB W14 WG IV Reflection Document.  Are the Basic Requirements being interpreted properly … or even adequately ??]

.

ANSWERS TO THE QUESTION …

The Greek Paper is included as Appendix I of CIB W14 WG IV Reflection Document … in order to show that Fire-Induced Progressive Damage is also an issue in buildings with a reinforced concrete frame structure.  It is more straightforward, here, to concentrate on buildings with a steel frame structure.

a)  Use of ‘Fire Resistance'(?) Tables for Structural Elements

We should all be familiar with these sorts of Tables.  The information they contain is generated from this type of standard test configuration in a fire test laboratory …

… and this sort of criterion for ‘loadbearing horizontal elements’ in a fire test standard …

A single isolated loaded steel beam, simply supported, is being tested.  As deflection is the only type of deformation being observed and measured … the critical temperature of the steel, i.e. the point when material strength begins to fail rapidly and the rate of beam deflection increases dramatically … is the sole focus for all stakeholders.

Using these Tables, it is very difficult to escape the conclusion that we are merely interior decorators … applying flimsy thermal insulation products to some steel structural elements (not all !) … according to an old, too narrowly focused, almost static (‘cold form’) recipe, which has little to do with how today’s real buildings react to real fires !

This ‘non-design’ approach is entirely inadequate.

.

With regard to the use of these Tables in Ireland’s Building Regulations (Technical Guidance Document B), I recently submitted the comments below to the relevant Irish AHJ.  These same comments could just as easily apply to the use of similar Tables in the Building Regulations for England & Wales (Approved Document B) …

” You should be aware that Table A1 and Table A2 are only appropriate for use by designers in the case of single, isolated steel structural elements.

In steel structural frame systems, no consideration is given in the Tables to adequate fire protection of connections … or limiting the thermal expansion (and other types of deformation) in fire of steel structural elements … in order to reduce the adverse effects of one element’s behaviour on the rest of the frame and/or adjoining non-loadbearing fire resisting elements of construction.

In the case of steel structural frame systems, therefore, the minimum fire protection to be afforded to ALL steel structural elements, including connections, should be 2 Hours.  Connections should also be designed and constructed to be sufficiently robust during the course of a fire incident.  This one small revision will contribute greatly towards preventing Fire-Induced Progressive Damage in buildings … a related, but different, structural concept to Disproportionate Damage

Disproportionate Damage

The failure of a building’s structural system  (i) remote from the scene of an isolated overloading action;  and (ii) to an extent which is not in reasonable proportion to that action.

Fire-Induced Progressive Damage

The sequential growth and intensification of structural deformation and displacement, beyond fire engineering design parameters, and the eventual failure of elements of construction in a building – during a fire and the ‘cooling phase’ afterwards – which, if unchecked, will result in disproportionate damage, and may lead to total building collapse.

Coming from this background and heritage … it is very difficult to communicate with mainstream, ambient structural engineers who are speaking the language of structural reliability, limit state design and serviceability limit states.

.

b)  NIST Report: ‘Best Practice Guidelines for Structural Fire Resistance Design of Concrete and Steel Buildings’ (NISTIR 7563 – February 2009)

At the end of Page 18 in NISTIR 7563 …

2.7.2 Multi-Storey Frame Buildings

In recent years, the fire performance of large-frame structures has been shown in some instances to be better than the fire resistance of the individual structural elements (Moore and Lennon 1997).  These observations have been supported by extensive computer analyses, including Franssen, Schleich, and Cajot (1995) who showed that, when axial restraint from thermal expansion of the members is included in the analysis of a frame building, the behaviour is different from that of the column and beam analyzed separately.

A large series of full-scale fire tests was carried out between 1994 and 1996 in the Cardington Laboratory of the Building Research Establishment in England.  A full-size eight-storey steel building was constructed with composite reinforced concrete slabs on exposed metal decking, supported on steel beams with no applied fire protection other than a suspended ceiling in some tests.  The steel columns were fire-protected.  A number of fire tests were carried out on parts of one floor of the building, resulting in steel beam temperatures up to 1000 °C, leading to deflections up to 600 mm but no collapse and generally no integrity failures (Martin and Moore 1997). “

Those were Experimental Fire Tests at Cardington, not Real Fires … on ‘Engineered’ Test Constructions, not Real Buildings !!   And … incredibly, for a 2009 document … there is no mention at all of World Trade Center Buildings 1, 2 or 7 !?!   Where did they disappear to, I wonder ?   Too hot to handle ???

Computer Model Verification and Validation (V&V) are very problematic issues within the International Fire Science and Engineering Community.  The expected outcome of a Model V&V Process, however, is a quantified level of agreement between experimental data (and, if available, real data) and model prediction … as well as the predictive accuracy of the model.

Now … please meditate carefully on the following …

” NCSTAR 1A (2008)  Recommendation D   [See also NCSTAR 1 (2005)  Recommendation 5)

NIST recommends that the technical basis for the century-old standard for fire resistance testing of components, assemblies and systems be improved through a national effort.  Necessary guidance also should be developed for extrapolating the results of tested assemblies to prototypical building systems.  A key step in fulfilling this Recommendation is to establish a capability for studying and testing components, assemblies, and systems under realistic fire and load conditions.

Of particular concern is that the Standard Fire Resistance Test does not adequately capture important thermally-induced interactions between structural sub-systems, elements, and connections that are critical to structural integrity.  System-level interactions, especially due to thermal expansion, are not considered in the standard test method since columns, girders, and floor sub-assemblies are tested separately.  Also, the performance of connections under both gravity and thermal effects is not considered.  The United States currently does not have the capability for studying and testing these important fire-induced phenomena critical to structural safety.

Relevance to WTC 7:  The floor systems failed in WTC 7 at shorter fire exposure times than the specified fire rating (two hours) and at lower temperatures because thermal effects within the structural system, especially thermal expansion, were not considered in setting the endpoint criteria when using the ASTM E 110 or equivalent testing standard.  The structural breakdowns that led to the initiating event, and the eventual collapse of WTC 7, occurred at temperatures that were hundreds of degrees below the criteria that determine structural fire resistance ratings. “

The design approach outlined in NISTIR 7563 is not only very flawed … it lacks any validity … because very relevant and important real fire data has been totally ignored.  The Cardington Experimental Fires were not all that they seemed.

.

c)  Current ISO TC92 International Case Study Comparison

Structural Fire Engineering Design of an Airport Terminal Building serving the Capital City of a large country (which shall remain nameless) … constructed using Portal Steel Frames …

My first concern is that the Structural Fire Engineering Design has been undertaken in isolation from other aspects of the Building’s Fire Engineering Design.

On Page 3 of the Case Study Report …

4.2 Objectives & Functional Requirements for Fire Safety of Structures

The fire safety objectives of the airport terminal emphasize the safety of life, conservation of property, continuity of operations and protection of the environment. “

Should these not be the Project-Specific Fire Engineering Design Objectives ?   Since when, for example, is ‘continuity of operations’ a concern in building codes ??

On Page 7 of the Case Study Report …

5.3  Identify Objectives, Functional Requirements & Performance Criteria for Fire Safety of Structure

The Fire Safety Objective of the Steel Structure:  There should be no serious damage to the structure or successive collapse in case of fire.

The Functional Requirements are defined as the followings:

(1)  Prevent or limit the structural failure in case of fire so as to prevent the fire from spreading within the compartment or to the adjacent fire compartment or the adjacent buildings (to prevent fire spread) ;

(2)  Prevent or limit the partial structural failure in case of fire so as to protect the life safety of the occupants and firefighters (to protect life safety) ;

(3)  Prevent or limit the structural deformation or collapse so as not to increase the cost or difficulties of the after-fire restoration (to reduce reconstruction cost).

One of the following Performance Requirements shall be met:

(1)  The load-bearing capacity of the structure (Rd) shall not be less than the combined effect (Sm) within the required time, that is Rd ≥ Sm.  (The maximum permitted deflection for the steel beam shall not be larger than L/400, and the maximum stress of the structure under fire conditions shall not be larger than fyT) ;   or

(2)  The fire resistance rating of the steel structure (td) shall not be less than the required fire resistance rating (tm), that is, td ≥ tm ;   or

(3)  Td – the critical internal temperature of the steel structure at its ultimate state shall not be less than Tm (the maximum temperature of the structure within required fire resistance time duration), that is Td ≥ Tm.  (300 ℃) “

Once again … we see an emphasis on critical temperature, beam deflection (only), and material strength.  L/400 is an impressive Fire Serviceability Limit State … a different world from L/20 or L/30 … but what about other important types of steel structural member deformation, e.g. thermal expansion and distortion ??

Furthermore … if there is a major fire in the area under the lower roof (see Section above) … because of structural continuity, any serious impact on the small frame will also have an impact on the large frame.  For Structural Fire Engineering reasons … would it not be wiser to break the structural continuity … and have the small and large portal frames act independently ?

It is proposed that the Portal Frames will NOT be fully fire protected … just the columns, up to a height of 8 metres only.  If ‘conservation of property’ and ‘continuity of operations’ are important fire engineering design objectives in this project … why isn’t all of the steel being fully protected ???   What would be the additional cost, as a percentage of the total project cost ?

What exactly is infallible about current Design Fires and Design Fire Scenarios ???   Not much.  And in the case of this particular building, should a ‘maximum credible fire scenario’ be at least considered ?

And … what is the fire protection material, product or system being used to protect the Portal Frames ?   Will it be applied, fixed or installed correctly ?   What is its durability ?   Will it be able to resist mechanical damage during the construction process … and afterwards, during the fire event ?   What is the reliability of this form of fire protection measure ??

So many questions …

.

.

END

Enhanced by Zemanta

Fire-Induced Progressive ‘Damage’ or ‘Collapse’ ? More …

2012-05-02:  Last week, I attended joint meetings of CIB W14: ‘Fire Safety’ … and ISO Technical Committee 92: ‘Fire Safety’, Sub-Committee 3: ‘Fire Threat to People and the Environment’ & Sub-Committee 4: ‘Fire Safety Engineering’ … in Thessaloniki (Salonika), Greece.

The relationship between these two independent groups is symbiotic … ISO TC 92 develops International Fire Standards, while CIB W14 is the pre-normalization forum for discussion and action on a comprehensive approach to Fire Research and Innovation.

I should add, here, that CIB W14’s Aims & Objectives were substantially updated at our meeting in Thessaloniki … and I presented the CIB Research WG IV Reflection Document: ‘Structural Reliability & Fire-Induced Progressive Damage’ for discussion … which was lively, but far too short !

.

While I was away, however, the following question was posed by Mr. Panagiotis Kotsovinos, on the Society of Fire Protection Engineers (SFPE-USA) Page of LinkedIn (http://www.linkedin.com/groups?gid=96627).

” I would like to please explain a bit more why the term ‘Fire-Induced Progressive Damage’ is preferred over ‘Fire-Induced Progressive Collapse’, and what is the confusion that exists widely as you say with the later definition ? “

Firstly, apologies for the late reply.  This was due to my absence from base … I am not continuously ‘plugged-in’ to the virtual environment while travelling.  But, I also wished to respond to this and other queries after some thought.  The issues raised are important.

Very briefly … it was NIST, in its 2005 Report, which introduced the term ‘Fire-Induced Progressive Collapse’ to a wide audience.  No definition, or elaboration, of this structural concept was provided in either the 2005 or 2008 Recommendations.  There is no confusion caused by ‘Fire-Induced’.

The reason I have been so quick to focus in on the distinction between ‘Damage’ and ‘Collapse’ is because we went through this whole debate, in Ireland … starting at the end of the 1980’s and continuing on through to the middle of 1990’s.  Because … in January 1987 … a Multi-Storey Apartment Block, called Raglan House, collapsed as a result of a gas explosion.  Two people were killed.  An examination of records at the time will reveal the same general confusion about technical terminology.  And … following the collapse, the Structural Engineering Profession was in disarray.

After a considerable amount of time witnessing, at close hand, these events … I formed the strong opinion that the proper connection of vertical and horizontal structural elements in a building was, and continues to be, a fundamental principle of all good structural engineering design … no matter what the height of the building.

.

Colour photograph showing World Trade Center Building No. 7 in ruins, after 9-11 in New York City ... when Fire-Induced Progressive Damage led to Disproportionate Damage, and finally to total building failure ... a Collapse Level Event (CLE). Click to enlarge.
Colour photograph showing World Trade Center Building No. 7 in ruins, after 9-11 in New York City ... when Fire-Induced Progressive Damage led to Disproportionate Damage, and finally to total building failure ... a Collapse Level Event (CLE). Click to enlarge.

.

Tackling the current confusion over technical terminology …

In 1987, Raglan House collapsed in Dublin.  In 2001, World Trade Center Building 7 collapsed in New York City.

In English … the word Collapse can have the following meanings, which are very broadly similar …

  • To fall down or cave in suddenly: the whole building collapsed ;
  • To fail completely ;
  • To break down or fall down from lack of strength ;
  • To fold (furniture, etc.) compactly or (of furniture, etc.) to be designed to fold compactly ;
  • The act or instance of suddenly falling down, caving in, or crumbling ;
  • A sudden failure or breakdown.

[from Latin, from collabi to fall in ruins, from labi to fall]

.

Black and white image reproducing Figure 1-1 in NIST Report: 'Best Practices for Reducing the Potential for Progressive Collapse in Buildings' (NISTIR 7396, February 2007) ... showing a bird's eye view of the Disproportionate Damage at Ronan Point, in England, which was caused by a gas explosion in 1968. Click to enlarge.
Black and white image reproducing Figure 1-1 in NIST Report: 'Best Practices for Reducing the Potential for Progressive Collapse in Buildings' (NISTIR 7396, February 2007) ... showing a bird's eye view of the Disproportionate Damage at Ronan Point, in England, which was caused by a gas explosion in 1968. Click to enlarge.

.

Please examine the photograph above.  Ronan Point (later demolished) was a 22 Storey Residential Tower Block in London, England.  In May 1968, this building suffered Disproportionate Damage as a result of a gas explosion.  As is clear from the photograph … it did not Collapse.

Disproportionate Damage

The failure of a building’s structural system:  (i) remote from the scene of an isolated overloading action;  and (ii) to an extent which is not in reasonable proportion to that action.

.

Let me now return to the CIB Research WG IV Reflection Document: ‘Structural Reliability & Fire-Induced Progressive Damage’ … where I began by stating …

Fire-Induced Progressive Damage in Buildings is distinguished from Disproportionate Damage – a related but different structural concept – by the mode of damage initiation, not the final condition of building failure.  Until this phenomenon is properly understood, and unless it is impeded, or resisted, by building design … Fire-Induced Progressive Damage will result in Disproportionate Damage … and may lead to a Collapse Level Event (CLE), which is entirely unacceptable to the general population of any community or society.

… and, later in the document, provided this definition …

Fire-Induced Progressive Damage

The sequential growth and intensification of structural deformation and displacement, beyond fire engineering design parameters, and the eventual failure of elements of construction in a building – during a fire and the ‘cooling phase’ afterwards – which, if unchecked, will result in disproportionate damage, and may lead to total building collapse.

.

Quickly Concluding …

‘Progressive Collapse’ is not the same as ‘Disproportionate Collapse’ … and while total building collapse may be the condition of final building failure, this will certainly not always be the case.  Therefore … ‘Damage’ is the more correct word to use than ‘Collapse’.

To go even further … it should not be necessary to have to use the word ‘total’ in the first sentence above.

.

Reminder … Please Read the Reflection Document …

The purpose of the Reflection Document issued by CIB W14 Research Working Group IV is to examine the ‘hot form’ structural concept of Fire-Induced Progressive Damage, and to propose a critical update to fire engineering design practice.  It is also intended to encourage a wider discussion about some of fire engineering’s fundamental tenets, and the future direction of our profession in a rapidly evolving trans-disciplinary approach to the design, construction and operation of a Safe and Sustainable Built Environment.

Let me repeat again … and as I emphasized in Greece … ALL comments on the Reflection Document are most welcome !

.

.

END

Enhanced by Zemanta

‘Fire-Induced Progressive Damage’ – New CIB W14 Document

2012-04-16:  Following the 9-11 World Trade Center Extreme Fire Event, in New York City …

The National Institute of Standards & Technology (NIST), in the USA, recommended that Fire-Induced Progressive Collapse be particularly considered in the case of …

  • High-Rise Buildings ;
  • Iconic Buildings ;
  • Buildings Having a Critical Function ;
  • Buildings of Innovative Design.

However, as recently discussed … in order to avoid the wide confusion which the term ‘Fire-Induced Progressive Collapse’ is continuing to cause at international level … the preferred term should now be Fire-Induced Progressive Damage.

AND … CIB Working Commission 14: ‘Fire Safety’ – Research Working Group IV: ‘Structural Reliability & Fire-Induced Progressive Damage’ … would strongly caution that Fire-Induced Progressive Damage and Disproportionate Damage are fundamental concepts to be applied in the design of all building types.

[ A height threshold of 5 Storeys for the consideration of Disproportionate Damage, in the Building Codes/Regulations of many jurisdictions, including Ireland, is entirely arbitrary.]

So … what is Fire-Induced Progressive Damage ?   And what is the relationship between this structural concept … and Disproportionate Damage ?

Leaving aside all of the crazy conspiracy theories about the collapse of World Trade Center Building No. 7 … is it possible for Conventional Fire Engineering to directly confront what actually happened ?   Unfortunately … the reaction still, even today, is to bury the head, ostrich-like, in the sand … and ignore WTC 7 and the 2008 NIST WTC Recommendations (Final Report NCSTAR 1A) !

Colour photograph showing World Trade Center Building No. 7 in ruins, after 9-11 in New York City ... when Fire-Induced Progressive Damage led to Disproportionate Damage, and finally to total building failure ... a Collapse Level Event (CLE) which is entirely unacceptable to the general population of any community or society. Click to enlarge.
Colour photograph showing World Trade Center Building No. 7 in ruins, after 9-11 in New York City ... when Fire-Induced Progressive Damage led to Disproportionate Damage, and finally to total building failure ... a Collapse Level Event (CLE) which is entirely unacceptable to the general population of any community or society. Click to enlarge.

.

Yesterday, on an adjoining page here … I uploaded a New CIB W14 International Reflection Document on ‘Structural Reliability & Fire-Induced Progressive Damage’, with 2 Appendices.  Scroll down to the section headed ‘April 2012’.

This is a Reflection Document issued by CIB W14 Research Working Group IV: ‘Structural Reliability & Fire-Induced Progressive Damage’;  its purpose is to examine the ‘hot form’ structural concept of Fire-Induced Progressive Damage, and to propose a critical update to fire engineering design practice.  It is also intended to encourage a wider discussion about some of fire engineering’s fundamental tenets, and the future direction of our profession in a rapidly evolving trans-disciplinary approach to the design, construction and operation of a Safe and Sustainable Built Environment.

The Document is written in a simple, generic language which is accessible to design disciplines outside the International Fire Science and Engineering Community.  The next phase of this CIB W14 Innovation & Research Project will certainly require the use of a more technical language, complex calculations, computer modelling, etc … and much closer liaison with CIB W14’s other Research Working Groups on Connections, Design Fires & Design Fire Scenarios, and Performance Criteria.

I wish to sincerely thank those individuals and organizations who have contributed to the work of our Research Working Group IV.

Finally, the myth surrounding NIST’s 9-11 WTC Recommendations, i.e. that they are only applicable in the case of Very Tall Buildings during rarely occurring extreme events … must be completely demolished, and obliterated from the face of the earth !

Climate Change Adaptation is already demanding a much higher level of building resilience.

.

Your Comments on this CIB W14 Reflection Document should be e-mailed to: fireox@sustainable-design.ie

C.J. Walsh, FireOx International – Ireland, Italy & Turkey.

Chair – CIB W14 Research WG IV.

.

.

Update 2012-04-20 …

In response to a discourteous and unprofessional comment about the above CIB W14 WG IV Reflection Document, posted by Mr. Morgan Hurley (Technical Director at the Society of Fire Protection Engineers in the USA) on the LinkedIn SFPE Group WebPage … I wrote, as follows, this morning …

Good Man Morgan !

Relax … there is no need to become defensive quite yet.  WG IV’s Reflection Document is simply intended to raise issues … ask questions … and solicit comments from within and, more importantly, from outside the International Fire Science and Engineering Community.

Perhaps of more direct relevance to the SFPE Membership, in the USA, might be the following …

NIST Report: ‘Best Practices for Reducing the Potential for Progressive Collapse in Buildings’ (NISTIR 7396 – February 2007) … is a good document on ‘disproportionate damage’, but it has nothing to say about ‘fire-induced progressive damage’.  These two structural concepts are related, but they are not the same.

When discussing Multi-Storey Steel Frame Buildings, on pages 18 and 19, of NIST Report: ‘Best Practice Guidelines for Structural Fire Resistance Design of Concrete and Steel Buildings’ (NISTIR 7563 – February 2009) … what happened to WTC Building 7 on 9-11, and the 2008 NIST WTC Recommendations (NIST NCSTAR 1A), are conveniently and completely ignored.  Instead, there is a launch straight into the BRE Fire Tests at Cardington, and computer calculations, in order to justify a very flawed design approach.  How crazy is that ?

Hope to see you there next week … we missed you at the last CIB W14 Meeting in Paris !

C.J.

.

.

END

Enhanced by Zemanta

2012 Review of Part B & TGD B – Irish Building Regulations

2012-03-02:  Please bear with me while I update you at the start of this post … rather than at the end, which would be more usual here … and logical.

[ In Ireland … a related problem, which continues to fester and cause a great nuisance in an everyday work environment … concerns the lack of proper, i.e. formal, recognition of electronic communications, and information in an electronic format, by public and private organizations … in spite of the following very clear legal text …

2000 Electronic Commerce Act (No. 27 of 2000)

Section 9 – Electronic Form not to Affect Legal Validity or Enforceability

Information (including information incorporated by reference) shall not be denied legal effect, validity or enforceability solely on the grounds that it is wholly or partly in electronic form, whether as an electronic communication or otherwise. ]

.

Yesterday afternoon (1 March 2012), we received the following e-mail communication from the Department of Environment, Community & Local Government (DECLG)

Folks,

Could you please send me your submissions in either Microsoft Word or Excel as it it easier to copy and paste into the format that is required , it is proving rather difficult to copy from a PDF document.

Thank You

Claire Darragh, Architecture / Building Standards, DECLG.

.

I immediately replied …

Dear Claire,

Further to your informal e-mail message, which we received just a short while ago …

Please note that this is not an acknowledgement that the FireOx International Submission was received by the Department … and we certainly do not wish that you copy and paste anything relating to its contents anywhere else.

IF this is a Proper Public Consultation Process … you must adapt internal DECLG systems to suit the Submissions !   We will be communicating with the Minister’s Office concerning this issue.

Once again, I would ask you to properly acknowledge receipt of our Submission, dated 2012-02-14.

.

In connection with the original FireOx International Submission … I would also like to take this opportunity to advise you that:

  • Due to an error in ISO (International Standards Organization) … the publication of ISO 21542: ‘Building Construction – Accessibility and Usability of the Built Environment’, on 12 December 2011, was not notified to people directly involved in its development and drafting, or to the participating national standards organizations ; 

and

  • In order to avoid the wide confusion which the term ‘Fire-Induced Progressive Collapse’ is continuing to cause at international level … the preferred term is now Fire-Induced Progressive Damage.

.

I have amended our Submission accordingly.

Kind regards.

C. J. Walsh, FireOx International – Ireland, Italy & Turkey.

.

.

2012-02-18:  The following is the text of  FireOx International’s Submission, dated 14 February 2012, to the Department of the Environment, Community & Local Government (DECLG) in Dublin … concerning the current review of the Irish Building Regulations Part B & TGD B … including, for good measure, some initial and very pertinent comments on the Irish Building Control Regulations.

None of these comments will come as any surprise to regular visitors here.

It should also be noted that the same comments are just as relevant in the case of the British (England & Wales) Building Regulations, Part B and Approved Document (AD) B !

.

Ms. Claire Darragh, Architecture & Building Standards Section, DECLG.

Dear Claire,

Thank you for this opportunity to advise the Department on some urgent and necessary improvements to Part B: ‘Fire Safety’ of the 2nd Schedule to the Building Regulations in Ireland … and its supporting Technical Guidance Document (TGD) B.

1.  Some Initial Comments

  • The continuing debacle of the Priory Hall Apartment Complex, in Donaghmede Dublin 13, is just the tip of a very large iceberg in Ireland.  Yet, when we now hear that there will be a ‘risk-based’ approach to Septic Tank Inspections, instead of an approach which involves inspecting all septic tanks … independently, competently and thoroughly … it is clear that the Minister, and senior officials in his Department, have failed to learn any lessons from ‘Priory Hall’.

What was happening on Irish construction sites during the Celtic Tiger boom years … has been happening for twenty years all over the country … more precisely, since the introduction of legal national building regulations in 1991, with NO effective building control … and, before that again, in those parts of the country outside of the major urban areas having legal building bye-laws AND effective building control, i.e. mandatory inspections by competent local authority personnel at the foundation level and drainage level of ALL projects … and, depending on the type of project, occasional or frequent inspections above ground level.

Over the years, local authority officials who carried out building bye-law inspections accumulated a considerable wealth of knowledge and understanding about local construction conditions and practices.  This valuable resource, widely used by the construction industry at the time, has now been diluted and discarded.

PLEASE LEARN THE LESSONS FROM ‘PRIORY HALL’ !!

In connection with ALL Applications for Fire Safety Certificates (Part B) and Disability Access Certificates (Part M) … competent and thorough inspections must, from now on, be carried out by local authority personnel to confirm proper implementation of Part B & M, respectively, of the 2nd Schedule to the Building Regulations.

Furthermore … while on site, local authority personnel must not be discouraged, or restricted, from dealing with any other Parts of the 2nd Schedule to the Building Regulations.  Under the present dysfunctional system, important horizontal linkages between different Parts of the 2nd Schedule are being widely disregarded and ignored, e.g. between Parts B & D, between Parts B & M, and between Parts B & A … or between Parts M & D, etc., etc !

  • European Union (EU) Council Directive 89/106/EEC has been repealed … and, instead, we now have EU Regulation No 305/2011 of the European Parliament and of the Council, of 9 March 2011, laying down Harmonised Conditions for the Marketing of Construction Products.

Unlike the earlier EU Directive … this Regulation, applicable in all EU Member States, is binding in its entirety.

And although Annex I of EU Regulation 305/2011 will enter into force from 1 July 2013 … the Department should now prepare for, and slowly begin the process of, incorporating all of the Annex I Basic Requirements for Construction Works into the 2nd Schedule of the Irish Building Regulations.

SEE BELOW …

.

2.  Firefighter Safety

Fully consistent with Basic Requirement for Construction Works 2(e), in Annex I of EU Regulation No. 305/2011 … Revise Part B Requirement 5 to read as follows …

B5  Firefighter Safety, and Access and Facilities for the Fire Service

A building shall be so designed and constructed that the safety of firefighters is adequately considered and, in the event of an outbreak of fire, that there is adequate provision for access for fire appliances and such other facilities as may be required to assist the fire service in the protection of life and property.

Two examples of issues which should be highlighted in a relevant revision/addition to TGD B’s Guidance Text:

  • The incorporation, in building designs, of alternative safe means of approach towards the scene of a fire by firefighters ;
  • The provision of wider staircases in buildings in order to facilitate the recovery of an injured/impaired firefighter during the course of firefighting operations.

.

3.  Protection of Vulnerable Building Users from Fire

The European Union ratified the United Nations Convention on the Rights of Persons with Disabilities (CRPD) on 23 December 2010.  Ireland has not yet ratified the Convention.

However … fully consistent with Ireland’s legal obligation, under Article 4.3 of the Treaty on European Union (TEU), to co-operate fully with EU Institutions in their implementation of this UN Convention … Revise Part B Requirement 1 to read as follows …

B1  Means of Evacuation in the Event of an Outbreak of Fire

A building shall be so designed and constructed that the protection of vulnerable building users is adequately considered and, in the event of an outbreak of fire, that there are adequate and accessible means of evacuation from the building to a place of safety remote from the building, capable of being safely and effectively used.

[ Use of the word ‘escape’, in the context of emergencies, should be strongly discouraged at all times. ]

Concerning TGD B’s Guidance Text … reference to ISO 21542: ‘Building Construction – Accessibility and Usability of the Built Environment’ will be more than sufficient.

.

Specifically relating to Adequate Protection of Vulnerable Building Users from Fire

NOTE WELL THAT BS 9999 (AND BS 5588:PART EIGHT)  IS (ARE)  ENTIRELY UNFIT FOR PURPOSE !!

Please carefully examine the attached PDF File – My Note for the National Standards Authority of Ireland:  ‘BS 9999:2008 & BS 8300:2009 – Impacts on Accessibility Design in Ireland & Implications for ISO Accessibility & Fire Safety Standards’ , dated June 2009.

.

4.  TGD B’s Appendix A – Performance of Materials and Structures

2 Important Notes should be added to Paragraph A21 – Structural Fire Design

  • In complying with Part B, reference should also be made to Part A of the 2nd Schedule of the Building Regulations, particularly Requirement A3 – Disproportionate Collapse ;

and

  • In order to show that a Fire Protection Material/Product/System for Structural Elements properly complies with Part D … it is also necessary, besides showing that it has been adequately fire tested, to show that the material/product/system is durable over a specified, reasonably long life cycle … and that it can adequately resist mechanical damage during construction of the building and, in the event of an outbreak of fire, during the course of that fire incident.

.

Specifically relating to Steel Structural Performance in Fire

You should be aware that Table A1 and Table A2 are only appropriate for use by designers in the case of single, isolated steel structural elements.

In steel structural frame systems, no consideration is given in the Tables to adequate fire protection of connections … or limiting the thermal expansion (and other types of distortion) in fire of steel structural elements … in order to reduce the adverse effects of one steel element’s behaviour on the rest of the frame and/or adjoining non-loadbearing fire resisting elements of construction.

In the case of steel structural frame systems, therefore, the minimum fire protection to be afforded to ALL steel structural elements, including connections, should be 2 Hours.  Connections should also be designed and constructed to be sufficiently robust during the course of a fire incident.  This one small revision will contribute greatly towards preventing Fire-Induced Progressive Damage in buildings … a related, but different, structural concept to Disproportionate Damage …

Disproportionate Damage

The failure of a building’s structural system  (i) remote from the scene of an isolated overloading action;  and (ii) to an extent which is not in reasonable proportion to that action.

Fire-Induced Progressive Damage

The sequential growth and intensification of structural distortion and displacement, beyond fire engineering design parameters, and the eventual failure of elements of construction in a building – during a fire and the ‘cooling phase’ afterwards – which, if unchecked, will result in disproportionate damage, and may lead to total building collapse.

.

With regard to the above … please carefully examine these 2 Series of Posts on FireOx International’s Technical Blog ( www.cjwalsh.ie ), beginning on the dates indicated …

  • 2011-10-25:  NIST’s (2005) Recommendations on the 9-11 WTC Building Collapses … GROUP 1. Increased Structural Integrity – Recommendations 1, 2 & 3 (out of 30) ;

and

  • 2012-01-18:  Progressive Collapse of WTC 7 – 2008 NIST Recommendations – Part 1 of 2 … GROUP 1. Increased Structural Integrity – Recommendation A … and GROUP 2. Enhanced Fire Endurance of Structures – Recommendations B, C, D & E (out of 13).

.

5.  TGD B’s Appendix F – Reference Standards

Add this Important New Standard …

  • ISO 21542 : 2011     Building Construction – Accessibility and Usability of the Built Environment

.

6.  TGD B’s Appendix G – Reference Publications

Add these Two Important Publications …

  • NIST (National Institute of Standards and Technology).  September 2005.  Federal Building and Fire Safety Investigation of the World Trade Center Disaster: Final Report on the Collapse of the World Trade Center Towers.  NIST NCSTAR 1.  Gaithersburg, MD, USA.

and

  • NIST (National Institute of Standards and Technology).  August 2008.  Federal Building and Fire Safety Investigation of the World Trade Center Disaster: Final Report on the Collapse of World Trade Center Building 7.  NIST NCSTAR 1A.  Gaithersburg, MD, USA.

.

Should you wish to receive further information on any of my comments … please consult FireOx International’s Technical Blog at  www.cjwalsh.ie … or contact me directly.

Please acknowledge receipt of this e-mail communication.

.

Kind regards.

C. J. Walsh, FireOx International – Ireland, Italy & Turkey.

.

.

END