Ar C.J. Walsh – Consultant Architect, Fire Engineer & Technical Controller – International Expert on : Sustainability Implementation + Accessibility (including Fire Safety) for All + Sustainable Fire Engineering
Within the professional discipline of Fire Engineering … either a building is Fire Safe, or it is not ; the design philosophy of the Fire Engineer is irrelevant. Similarly, building designers must now begin to think and act in the simple terms of a building being either Accessible, or not. Too many pointless discussions, and too much petty squabbling, about constrained and constraining accessibility philosophies have wasted valuable time, energy and resources.
.
Colour photograph showing a typical, everyday scene in countries all over the world … a young person in a manual wheelchair, independently attempting to mount an external flight of steps in front of a building entrance. . Reality Check: A Universal, Dismally Inaccessible Built Environment ! . Click image to enlarge.
.
Building Accessibility encompasses the complete cycle of Independent Use, in a dignified manner and on an equal basis with others … and includes the approach, entry and use of a building, its facilities and information systems … Egress during normal / ambient conditions and removal from the vicinity of the building … and most importantly, safe Evacuation during a fire emergency to a Place of Safety which is remote from the building and reached by way of an accessible route.
.
Colour image illustrating the difference between Equality and Equity. Everybody is equal, and must be treated equally … but the measures necessary to achieve this in real life must, in many cases, be equitable. . Human Ability and Behaviour is a continuum … a gentle gradient on which every person functions and acts at different levels due to Environmental and Personal Factors. . Click image to enlarge.
.
To be Accessible, a building must meet a long and complex list of inter-related Accessibility & Usability Design Criteria sufficiently well, i.e. the building must work properly for building occupants and users. The design target is Effective Accessibility … not half-baked accessibility, partial accessibility, the minimal accessibility required by building codes, or token accessibility.
On the other hand, and taking additional account of the current CoronaVirus / CoVID-19 Pandemic … the construction and operation target must be Successful Implementation, i.e. the finished building design, as constructed and operated, must provide a consistently high degree of safety, convenience and comfort for potential occupants and users during the lifetime of the building.
.
Colour photograph showing the post-fire scene of a devastated Lift Lobby with an abandoned Manual Wheelchair. 25 people died and 123 were injured in a Jazan Hospital Fire, Saudi Arabia, which occurred on 24 December 2015. The fire broke out in the hospital’s Intensive Care Unit and Maternity Ward. Click photograph to enlarge.
.
People with Activity Limitations … those people, of all ages, who are unable to perform, independently and without assistance, basic human activities or tasks – because of a health condition or physical / mental / cognitive / psychological impairment of a permanent or temporary nature … are a significant vulnerable group in every community, in every society, and include people with disabilities, children under the age of 5 years, frail older people, women in the later stages of pregnancy, and people with health conditions, etc.
Fire Safety Codes and Standards for healthy, able-bodied, agile adults using buildings exist in almost every country ; these people can take for granted that buildings are fire safe for them !
However, guidelines concerning Fire Safety for People with Activity Limitations / Fire Safety for ALL (if those guidelines exist at all) are usually technically inadequate, entirely tokenistic and/or blatantly discriminatory ; these people must assume that there is a serious risk to their safety every time they enter a building. For them, this is a very significant barrier to their personal development, participation and social inclusion ; it is a clear and present violation of their human rights !
Forcefully mandated in the United Nations Convention on the Rights of Persons with Disabilities, adopted on 13 December 2006 … the UN CRPD’s Principal Aim is to ensure that the Human Environment (social, built, economic, virtual, and institutional) is sufficiently accessible to facilitate the safe exercise and enjoyment of those rights, protections and freedoms set down in the 1948 Universal Declaration of Human Rights (UDHR), and subsequent International Rights Instruments, by a vulnerable and major section of the population in all of our communities.
.
Colour photograph showing the scene of a raging fire in London, on 14 June 2017. 72 people died and many more were injured in this 24 Storey, 120 Apartment Residential Building. Vulnerable People, including people with activity limitations, refugees, and immigrants with a poor grasp of the English language lived at various heights throughout the Tower. . A serious design flaw in this building (among many, many others), i.e. a lack of Effective Accessibility … only one narrow, atrociously detailed staircase serving the entire building, lifts/elevators which were useless in a fire emergency, and no areas of rescue assistance adjoining the staircase … had a profoundly negative impact on Firefighter Operations and Safety on the night of 14 June and the following day. . Click photograph to enlarge.
.
It is time to Entirely Eradicate current obsolete, professionally negligent, incompetent and ridiculous approaches to Building Design which result in …
Fire Safety for SOME but not for ALL
Accessibility for SOME but not for ALL
Intricately inter-related … ‘Fire Safety for All’ is a vital component of ‘Accessibility for All’.
.
Colour image / Presentation overhead showing how building designers face a critical choice in everyday practice … Legal or Ethical … Beyond Codes ?!?!? . Legal Compliance is Never Enough. . Click image to enlarge.
Essential Considerations for National Authorities Having Jurisdiction (AHJ’s):This Planet is Our Common Home – Be a Good Neighbour to Other Countries (Cuba is a Good Example, USA is a Bad Example) … Global Solidarity & Multilateral Collaboration in Co-Operation with the World Health Organization (WHO) … Act Fast … Perfection is the Enemy of the Good … The Precautionary Principle … Test-Test-Test … Return Test Results within 24 Hours … Trace Contacts within the Next 24 Hours … Collect, Collate and Openly Share Reliable Data & Statistics … Vulnerable People Require Equitable Safety Measures … Uphold and Protect Human & Social Rights.
[ Vulnerable People: Those people – in a community, society or culture – who are most at risk of being physically, psychologically or sociologically wounded, hurt, damaged, injured, or killed … and include, for example, People with Disabilities, Young Children, People with Health Conditions, Frail Older People, Women in Late Pregnancy, Refugees, Migrants, Prisoners, the Poor, and Homeless. ]
Essential Considerations for Each Person in a Community: Wash Hands Often and Properly (see Video below) … Wear a Mask in Outdoor and Indoor Public Spaces (see WHO Guidance below) … Social Separation / Physical Distancing … Be Careful, Always … Pay Attention to Your Mental Health (see UN Policy Brief below).
.
First Affiliated Hospital, Zhejiang University School of Medicine, China
The First Affiliated Hospital has treated 104 patients who tested positive for CoVID-19 in 50 days. It has achieved zero deaths in patients diagnosed, zero patients misdiagnosed, and zero infections in medical staff. Its experts documented real treatment experience when combating the virus, 24 hours a day, and quickly published this Handbook.
Public Health Emergencies often lead to Stigma, Discrimination and Abuse towards certain communities and social groups, or affected people. Within the context of CoVID-19, this has already happened … with the disease being recklessly and maliciously associated with a specific population or nationality.
Independent Oversight & Advisory Committee for the WHO Health Emergencies Programme
Established to facilitate on-line communication and collaboration internationally, as well as to provide Frontline Medical Teams around the world with the necessary communication channels to share practical experience about fighting, controlling and overcoming the pandemic.
An Agency of the European Union (EU) … ECDC is closely monitoring the CoVID-19 Outbreak, providing Public Health Guidance and advice on Response Activities to EU Member States and the EU Commission.
The European Commission, together with several Partners, launched this Platform on 20 April 2020 … to enable the rapid collection and sharing of available Research Data. The Platform, part of the ERAvsCorona Action Plan (download PDF File, 153 Kb), is a significant effort to support Researchers in Europe and around the World in the fight against the CoronaVirus pandemic.
Vulnerable People, such as Those with Activity Limitations (#PwAL) or Disabilities (#PwD), are more impacted by #CoronaVirus/#CoVID19. These impacts can be mitigated if simple Self-Protection Measures are taken.
As Fire Departments and local Authorities Having Jurisdiction (AHJ’s) continue planning to respond to CoronaVirus/CoVID-19 occurrences in their communities, the IAFC Coronavirus Task Force has developed a guide to identify best practices … and key recommendations which are based largely on guidance from the U.S. Centers for Disease Control and Prevention (CDC – https://www.cdc.gov/) and the World Health Organization (WHO – https://www.who.int/emergencies/diseases/novel-coronavirus-2019). When planning for CoVID-19, Fire Chiefs must also be sure to collaborate with local Stakeholders, both individuals and organizations !
2019-11-11:Kensington and Chelsea’s wilful disdain for the Health, Safety and Welfare of ALL the residents within its functional area … and knowing neglect of its legal and ethical Duty of Care towards ALL … resulted in a significant number of people with activity limitations living high up in Grenfell Tower prior to June 2017 … in spite of the now incontrovertible fact that, in the event of a fire emergency, many would be left behind … to die.
‘All human beings are born free and equal in dignity and rights.’
Article 1, 1948 Universal Declaration of Human Rights
Colour photograph showing a Firefighter watching the horrific fatal fire scene at Grenfell Tower in London, on 14 June 2017, from a nearby balcony. Click to enlarge.
London Fire Brigade was an easy target for the Grenfell Fire Inquiry’s Phase 1 Report, made all the more so following some careless, insensitive and ignorant public comments by its Commissioner, Dany Cotton. However, we must clearly distinguish between the behaviour of LFB’s Frontline Firefighters, who were brave and dedicated despite inadequate training, and lack of proper equipment, back-up resources and personnel strength … and LFB’s Senior Commanders … which is another matter.
Colour photograph showing the London Fire Brigade (LFB) Commissioner, Dany Cotton. In order to ensure that transformation of the LFB actually takes place in the short term, and is fully effective, Dany Cotton and all of her Senior Commanders must resign now, or be fired ! Click to enlarge.
In England … there is widespread indifference, and some rabid resistance, to answering the desperate needs, and mitigating the agonizing plight, of Vulnerable Building Users during fire emergencies … which includes people with activity limitations, children under 5 years of age, frail older people (not All older people !), women in late stage pregnancy, people with disabilities, refugees, migrants, the poor, and people who do not understand the local culture or cannot speak the local language. British National Standard B.S.9999 (not solely those sections previously contained in B.S.5588:Part 8) and England’s National Building Regulations – Approved Document B: ‘Fire Safety’ – offer only token, i.e. inadequate, protection for vulnerable people in fire emergencies. When a senior representative of BSI, the British Standards Institution, was directly approached by me, and requested to open up B.S.9999 for meaningful updating … the answer was a firm “NO” ! The same attitude is deep-seated among fire research organizations in the country, and among people who develop computer fire evacuation models.
Presentation Overhead, in colour, showing the ‘Fire Safety for All’ Matrix, which outlines the scope of its application in the Human Environment and the different social groups to be targeted. Balanced consideration must be given to people who use wheelchairs (physical function impairment) … and to people with visual, hearing, psychological, and mental/cognitive impairments … and to other vulnerable building users, e.g. people with health conditions. Click to enlarge. Matrix developed by CJ Walsh.Presentation Overhead showing the definition of ‘people with activity limitations’, with its equivalent French translation … also showing from where this term is derived … and who this term includes. During a fire emergency, confused and/or confusing disability-related language costs lives ! Click to enlarge.
.
Grenfell Fire Inquiry’s Phase 1 Recommendations – Chapter #33
After hearing the first media reports about the tough Recommendations aimed at London Fire Brigade, I had naturally expected that the other Phase 1 Recommendations would be equally as tough. But NO … they are far from comprehensive … they are fragmentary, lack depth and any sort of coherence. Specifically with regard to Vulnerable Building Users, the Recommendations are pathetically and disgracefully inadequate !
And in case there is any doubt, the status quo in England – and to be fair, in many other countries as well – is entirely unacceptable !!
Few people realize that the fire safety objectives in current fire regulations/codes are limited and constrained. To implement changes to the flawed regulations in England, it will take many years … and, based on recent past history, implementation will be incomplete and unsatisfactory. Residents in high-rise buildings, whether public or private, must no longer wait in vain for this to happen. Instead, the time has arrived to become proactive, and to immediately initiate their own comprehensive programmes of Self-Protection In Case Of Fire … which go far and beyond the pathetic Recommendations in Moore-Bick’s Phase 1 Report.
Fires Similar To Grenfell Tower Are Frequent
[ Paragraph #33.5 ] … although not unprecedented, fires of the kind that occurred at Grenfell Tower are rare.
[ Response ] Not true … misleading, and a complete fallacy !
Just since 2010, fires similar to Grenfell Tower have occurred in South Korea, many in the United Arab Emirates, France, Chechnya, Australia, Azerbaijan, Russia, and most recently in Turkey. Each one of these fires has been recorded and illustrated on our Twitter Account: @sfe2016dublin. Seeing, and understanding, this striking pattern of unusual fire behaviour … a competent person would react and plan accordingly.
Effective Fire Compartmentation Is A Delusion … A Fantasy !
[ Paragraph #33.5 ] Effective compartmentation is likely to remain at the heart of fire safety strategy and will probably continue to provide a safe basis for responding to the vast majority of fires in high-rise buildings.
[ Response ] Not true … demonstrates a fundamental flaw in European fire safety strategizing !
In an environment of lax or non-existent compliance monitoring … the quality of architectural/fire engineering design and the reliability of related-construction will both, inevitably, be poor and unacceptable. Fire loads in today’s residential buildings are also far higher than a generation ago, for example, because of more electrical/electronic equipment and synthetic furnishings. And whatever about first-built, i.e. whether it’s good, bad or ugly, later alterations and other construction work will typically compromise the original performance of fire resisting doorsets and service penetration fire sealing. Modern ‘green’ building materials and construction methods are further aggravating these problems. A competent person would be aware of fire research at the UL Laboratories, in the U.S.A., which confirmed the above developments.
‘ Rigorous enforcement of building codes and standards by state and local agencies, well trained and managed, is critical in order for standards and codes to ensure the expected level of safety. Unless they are complied with, the best codes and standards cannot protect occupants, emergency responders, or buildings.’
U.S. National Institute of Standards and Technology. Final Report on the Collapse of the World Trade Center Towers. NIST NCSTAR 1. 2005.
‘Stay Put’ Policies Are Criminal
[ Paragraph #33.5 ] However, in the case of some high-rise buildings it will be necessary for building owners and fire and rescue services to provide a greater range of responses, including full or partial evacuation. Appropriate steps must therefore be taken to enable alternative evacuation strategies to be implemented effectively.
[ Paragraph #33.15 ]e. that policies be developed for managing a transition from ‘stay put’ to ‘get out’ ;
[ Response ] Too little … and far too late !
[ Solution ] Two fatal fires separated in time and space … the 2009 Lakanal House Fire, in London, and the 2017 Marco Polo High-Rise Apartment Building Fire, in Honolulu, continue to clearly demonstrate that effective fire compartmentation is a delusion. Even if carried out by a competent person … it is not possible to establish with reasonable certainty, by means of a visual/surface building inspection alone, whether or not fire compartmentation is effective in an existing building. The London and Honolulu buildings were not fitted with any active fire suppression system, e.g. fire sprinklers or a water mist system.
Buildings must remain structurally ‘serviceable’, not merely structurally ‘stable’, for a Required Period of Time. See the Presentation Overhead below.
Presentation Overhead, in colour, explaining the concept of ‘Structural Reliability’ in fire conditions … and defining ‘Required Period of Time’, during which a building must remain serviceable. Click to enlarge.
Authorities Having Jurisdiction (AHJ’s), firefighters, client organizations, design teams, and building owners/managers must not, therefore, direct, or even suggest, that any of its building users wait (‘stay put’) in that building during a fire emergency. A competent person always connects building fire performance with its structural performance, and vice versa … and always learns from the evidence of ‘real’ fatal fires.
All Lifts/Elevators Must Be Used For Fire Evacuation
[ Paragraph #33.13 ] When the firefighters attended the fire at Grenfell Tower they were unable to operate the mechanism that should have allowed them to take control of the lifts. Why that was so is not yet known, but it meant that they were unable to make use of the lifts in carrying out firefighting and search and rescue operations. It also meant that the occupants of the tower were able to make use of the lifts in trying to escape, in some cases with fatal consequences.
[ Response ] There is a ridiculous assumption in Moore-Bick’s Phase 1 Report that it is only firefighters who use lifts/elevators during a fire emergency, and that it is dangerous for anybody else to use them.
[ Solution ] In order to adequately protect Vulnerable Building Users … ALL lifts/elevators in a building must be capable of being used for fire evacuation during a fire emergency.
Until such time as firefighters arrive at a building fire scene in sufficient strength and are properly prepared to carry out effective firefighting and rescue operations … Firefighter Lifts/Elevators must be used for the fire evacuation of building occupants/users. Prior liaison and pre-planning with local fire services is always necessary with regard to the use of firefighting lifts/elevators for the evacuation of occupants/users.
Colour photograph showing a typical sign outside most lifts/elevators around the world … ‘In The Event of Fire, Do Not Use Lift’. This is a pre-historic dinosaur of a policy which places Vulnerable Buildings Users in immediate and very serious danger during a fire emergency. Click to enlarge.
A fundamental principle of fire safety design is that there must be alternative, safe and accessible evacuation routes away from the scene of a fire, which can occur in any part of a building during its life cycle ; these evacuation routes must be capable of being used by all building users, including people with activity limitations.
This is why there must always be at least 2 Fire Evacuation Staircases in High-Rise Residential Buildings !
The location of lifts/elevators and lobbies, within peripheral building cores, must always be considered in relation to the position of adjacent fire protected evacuation staircases, which must be easily found by building occupants/users, and the areas of rescue assistance adjoining those staircases.
To be used for fire evacuation, a lift/elevator must be ‘fit for its intended use’, must operate reliably during a fire emergency, and must comprise a complete building assembly which meets specific performance criteria.
A Lift/Elevator Fire Evacuation Assembly is an essential aggregation of building components arranged together – comprising a lift/elevator, its operating machinery, a hard-construction vertical shaft enclosure, and on every floor served by the lift/elevator a sufficiently large, constantly monitored lobby for people to wait in safety and with confidence, all robustly and reliably protected from heat, smoke, flame and structural collapse during and after a fire – for the purpose of facilitating the safe evacuation of building occupants/users throughout the duration of a fire emergency.
If a building is located in a Seismic Zone, Lift/Elevator Fire Evacuation Assemblies which can safely operate during an earthquake must always be specified and installed.
Gravity Evacuation Chair Devices, which are not electrically-powered and operate by gravity, facilitate downward movement, only, on straight flights of stairs. Having descended a staircase, with the user having left his/her wheelchair behind, these devices are not fully stable when travelling the long horizontal distances necessary to reach an external ‘place of safety’ remote from a building, perhaps over rough terrain.
Colour photograph showing a Gravity Evacuation Chair and how it is used during a fire emergency. Click to enlarge.
If lifts/elevators in existing buildings undergo a major overhaul, or if they are replaced, they should then be made capable of use for fire evacuation.
Lifts/elevators used for fire evacuation must always have a fire protected electrical supply which is separate from the main building electrical supply, in order to ensure that they can continue to operate without interruption during a fire emergency.
In addition to conventional passive fire protection measures, Lift/Elevator Lobbies must also be protected by an active fire suppression system. Water mist is the preferred fire suppression medium, because it is user-friendly, will not greatly interfere with user visibility, uses far less water compared to water sprinklers, and is also climate-friendly. Furthermore, because people with activity limitations will be waiting for evacuation in lift/elevator lobbies, building designers and managers must ensure that these lobbies are properly fitted out with appropriate fire safety equipment, facilitation aids, smoke hoods, signage and communications, etc., etc.
Proper Use of Personal Emergency Evacuation Plans (PEEP’s)
[ Paragraph #33.22 ]f. that the owner and manager of every high-rise residential building be required by law to include up-to-date information about persons with reduced mobility and their associated PEEP’s in the premises information box ;
[ Response ] There is No Recommendation or explanation in Moore-Bick’s Inquiry Phase 1 Report concerning the ‘what’, ‘why’ or ‘how’ of PEEP’s.
[ Solution ] A Personal Emergency Evacuation Plan is a person-specific and location-specific document, and is an integral part of the overall Fire Emergency Management Plan for a building. It is intended for regular occupants/users who may be vulnerable in an emergency situation, i.e. those with limited abilities in relation to self-protection, independent evacuation to an external place of safety remote from the building, and active participation in the building’s fire emergency procedures.
In new buildings, which are effectively accessible (including fire safe) for all, Personal Emergency Evacuation Plans are not necessary.
In existing buildings, Personal Emergency Evacuation Plans must not be used to limit or restrict access by an individual to any part of a building and its facilities. To ensure this, sufficient accessibility works must be carried out and appropriate management procedures put in place.
In buildings of historical, architectural and cultural importance, where the historical, architectural or cultural integrity of the building must be protected, Personal Emergency Evacuation Plans may limit or restrict access to parts of a building and some of its facilities. Refer to the ICOMOS 1964 International Charter for the Conservation and Restoration of Monuments and Sites.
There are No Recommendations in Moore-Bick’s Inquiry Phase 1 Report concerning these critical issues.
[ Solution ] There are many fire safety problems associated with high-rise and tall buildings. Evacuation by staircases alone can take many hours ; the physical exertion involved in descending even 10 floors/storeys by staircase is too much for many able-bodied people and is impossible for most vulnerable building occupants/users, particularly people with activity limitations. Passive fire protection of staircases, alone and/or supplemented by pressurization to prevent smoke ingress, is far too unreliable. And heavily equipped firefighters cannot be expected to ascend more than 10 floors/storeys by staircase before carrying out arduous firefighting and search/rescue operations. Furthermore, uninterrupted lift/elevator shafts, extending throughout the full height of a tall building, pose a significant risk of uncontrolled fire spread.
Colour photograph showing the very narrow, single staircase in the Grenfell Tower, London. How anybody – ANYBODY – could ever imagine that this staircase would be adequate to serve the fire evacuation needs of a diverse occupant population in a high-rise residential building is beyond belief ! A Syndrome is a cluster of symptoms which occur together and can be taken as indicative of a particular design abnormality. Click to enlarge.Presentation Overhead, in colour, illustrating a sufficiently wide fire evacuation staircase … minimum width 1.5m between handrails … which will accommodate Contraflow and the Assisted Evacuation of people in wheelchairs … with a sufficiently large, directly adjoining Area of Rescue Assistance … which will accommodate people unable to independently evacuate during a fire emergency. The space provided in an Area of Rescue Assistance, on each floor/storey, is calculated in relation to the design occupant/user population of a building. Even if a building is fully sprinklered, an Area of Rescue Assistance must adjoin every fire evacuation staircase. Click to enlarge. Staircase design by CJ Walsh.
A Floor of Temporary Refuge is an open, structurally robust floor/storey in a tall building – having an exceptionally low level of fire hazard and risk, ‘intelligently’ fitted with a suitable user-friendly and climate-friendly fire suppression system, e.g. water mist, and serviced by sufficient accessible, fire protected lifts/elevators capable of being used for evacuation during a fire emergency ; it is designed and constructed to halt the spread of heat, smoke and flame beyond that floor/storey, and is intended as a place of temporary respite, rest and relative safety for building users before continuing with evacuation, and as a forward command and control base for firefighters.
In a high-rise, tall, super-tall or mega-tall building, every 20th floor must be a Floor of Temporary Refuge, even if the building is co-joined with another building, or there are sky bridges linking the building with one or more other buildings.
Special provision must be made, on these floors, for accommodating large numbers of building occupants/users with activity limitations … and because people will be waiting on Floors of Temporary Refuge, perhaps for extended periods of time, building designers and managers must ensure that these floors/storeys are properly fitted out with appropriate fire safety equipment, facilitation aids, smoke hoods, signage and communications, etc., etc.
Presentation Overhead, in colour, illustrating and explaining the design concept of Floors of Temporary Refuge. Click to enlarge.
.
Conclusion: Fire Engineering Capacity in England is Lacking
In England … the very important 2005 and 2008 U.S. NIST Recommendations following the 9-11 (2001) Attacks on the World Trade Center, in New York City, were completely ignored. Following the 2009 Lakanal House Fire, in London, the 2013 Coroner’s Recommendations were only partially implemented.
With regard to Vulnerable Building Users … there is NO capacity within the English Fire Establishment, including the National Fire Chiefs Council (NFCC), English Authorities Having Jurisdiction (AHJ’s), and its Building Design and Fire Engineering Communities … to properly respond to … never mind understand … the Fire Safety, Protection and Evacuation for ALL in Buildings.
2019-07-26: This time last month, in June … I was visiting a hot and humid Hong Kong and Macau, only 1 hour apart on a sea ferry, in China’s Bay Area … to make a Keynote CPD Presentation on Fire Safety for All – Nobody Left Behind ! in the Hong Kong Institute of Architects … and following that up with a full morning Workshop and an afternoon Plenary Presentation at the large 2019 Rehabilitation International Asia-Pacific Region Conference, in Macau, later in the week.
2019 Rehabilitation International Asia-Pacific Conference (Macau) – 26 to 28 June
The Theme of this 3-Day Conference, in #Macau, was Together, Leaving No One Behind, In Disability-Inclusive & Rights-Based Progress. Attended by 1,500 delegates from 30 different countries, the event also gathered together more than 250 international experts, practitioners, academics and researchers from all over the world.
Two Exhibitions, visited by 6,000 people, were organized alongside the Conference: 1) ‘Facilitation and Mobility Aids + Assistive Technologies’ … and 2) ‘Art’.
It is worthwhile noting that #China ratified the U.N. Convention on the Rights of Persons with Disabilities (#CRPD) on 1 August 2008 … but has not yet signed, never mind ratified, the Convention’s Optional Protocol … a clear signal of current political intent which, hopefully, will change in the not-too-distant future. Every year, Hong Kong and Macau submit reports to Beijing regarding CRPD compliance status and implementation.
Colour photograph showing CJ Walsh, as he addresses a Plenary Session on Fire Safety for All – Nobody Left Behind ! at the 2019 Rehabilitation International Asia-Pacific Region Conference, in Macau. Click to enlarge.
.
Colour image showing the Matrix of ‘Fire Safety for All’ … a Priority Theme of Sustainable Fire Engineering … which is particularly concerned with the fire safety of #PwAL’s (People with Activity Limitations), but also with #PwD’s (People with Disabilities). After the 2017 Grenfell Tower Fire, in London, it is important that these concerns stretch to include the #Poor, #Refugees and #Migrants. Click to enlarge.
Without being able to use a #Lift/#Elevator for Fire Evacuation in a building … there is No Fire Safety for All !
In a developing fire incident, People with Activity Limitations must be provided with a safe, alternative evacuation route – just like all other building users – which is a Fundamental Principle of all Fire Engineering. However … just one #User/#Occupant Fire Evacuation Lift/Elevator in a building is an empty, meaningless, Token Gesture !
Colour photograph showing the participants from 30 different countries who attended the 2019 Rehabilitation International Asia-Pacific Region Conference. The venue was The Venetian Macau Hotel. Click to enlarge.
.
Fire Safety for All must be considered at the start of the Design Process. Colour image explaining how #Buildings must remain #Serviceable, not merely Structurally Stable, for a minimum Required Period of Time. Click to enlarge.
.
‘Fire Safety for All’ on Macau TV News … Friday night, 28 June 2019 … my friend and colleague, Ar Joseph Kwan (Architect & Accessibility Consultant based in Hong Kong), is the person being interviewed …
.
.
Hong Kong Institute of Architects CPD Seminar – 24 June 2019
Continuing Professional Development (#CPD) is an important aspect of Ethical Architectural Practice. Arriving drenched in a heavy rain downpour on the Monday evening … I was not surprised, therefore, to find that this Seminar was well attended by local architects. Representatives of HK Authorities Having Jurisdiction (#AHJ’s), and Local Fire Services, as well as senior personnel involved in the development of the HK Code of Practice for Fire Safety in Buildings and the HK Barrier Free Design Manual were active participants in the panel discussion afterwards.
Colour image showing the Title Page of CJ Walsh’s Keynote CPD Presentation on ‘Fire Safety for All – Nobody Left Behind !’. This Page also signals how ‘Fire Safety for All’ is integrated into the wider context of Sustainable Design. Click to enlarge.
.
Colour photograph showing CJ Walsh, as he makes a Keynote CPD Presentation on ‘Fire Safety for All – Nobody Left Behind !’ in the offices of the Hong Kong Institute of Architects. Click to enlarge.
.
‘Fire Safety for All’ on Twitter … @firesafety4all